Calibrating the Header Sensors
Sensor calibration programs the windrower control module (WCM) with settings for the attached header.
Calibrating the Header Height Sensor
NOTE:
•
The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its configuration for each header type. For more information, refer to
•
The engine
MUST
be running to perform this procedure.
1007188
C###
X###
WINDROWER SETUP?
NO/YES
A
B
Figure 3.148: M205 CDM Programming Buttons
1.
Start the engine.
2.
Press PROGRAM (A) and SELECT (B) on cab display
module (CDM) to enter programming mode.
•
WINDROWER SETUP? is displayed on the
upper line.
3.
Press SELECT (B) until CALIBRATE SENSORS? is
displayed on the upper line.
•
NO/YES is displayed on the lower line.
1009981
CALIBRATING HEIGHT
RAISE HEADER HOLD
C###
X###
C
B
A
Figure 3.149: M205 Header Height Calibration
4.
Press right arrow (B) to select YES. Press SELECT (C).
•
TO CALIBRATE SELECT is displayed in upper line.
5.
Press left (A) or right (B) arrow until HEADER HEIGHT
is displayed on the lower line. Press SELECT (C).
•
CALIBRATING HEIGHT is displayed on the
upper line.
•
RAISE HEADER HOLD is displayed on the
lower line.