215104
105
Revision A
4.3
Configuring the Windrower
The windrower can be configured to meet changing crop conditions, activate newly added options, indicate a change of
header type, or increase operator comfort level.
4.3.1
Setting the Header Knife Speed
This topic does not apply to rotary disc headers.
NOTE:
The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM) automatically
adjusts its programming for each header.
1011760
CXXX
EXXX
WINDROWER SETUP?
NO/YES
A
B
C
Figure 4.17: CDM Programming Buttons
1.
Turn the ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (C) on the CDM to enter
programming mode.
•
WINDROWER SETUP? is displayed on the upper line.
•
NO/YES is displayed on the lower line.
3.
Press right arrow (B) to select YES. Press SELECT (C).
•
SET KNIFE SPEED? is displayed.
•
The current knife speed is displayed on the lower line.
1011803
CXXX
EXXX
SET KNIFE SPEED
#### SPM
D
C
B
A
Figure 4.18: Knife Speed Setting
4.
Press left (B) or right (C) arrows to select knife speed. Press
SELECT (D).
5.
Press PROGRAM (A) to exit programming mode or press
SELECT (D) to proceed to next WINDROWER SETUP action.
4.3.2
Setting the Knife Overload Speed
When the knife speed drops below the knife overload speed setting , this indicates the knife drive is overloaded, and a
warning is displayed on the cab display module (CDM). The knife overload speed is set at 75% of knife speed.
NOTE:
•
The header
MUST
be attached to the windrower to perform this procedure. The cab display module automatically
adjusts its programming for each header.
•
The recommended knife overload speed is 75% of knife speed.