3.10.3
Controls
A – Temperature Control Dial
controls cab temperature.
• Clockwise: Increases temperature.
• Counterclockwise: Decreases temperature.
B – Blower Switch
controls the blower speed.
• OFF / LOW / MEDIUM / HIGH
C – Air Conditioning Switch
controls the A/C system.
• OFF: A/C does not operate.
• ON: A/C operates with blower switch ON.
Figure 3.22: Climate Controls
A - Temperature Control
B -Blower
C - Air Conditioning
IMPORTANT:
To distribute the refrigerant oil throughout the A/C
system, perform the following steps when starting the
windrower after more than one week of storage:
1. Ensure heater shut-off valve at engine is OPEN. Refer
to
3.10.1 Heater Shut-Off, page 47
2. Turn blower switch to the
fi
rst position,
turn
temperature control switch to MAXIMUM heating, and
A/C control to OFF.
3. Start engine and operate at low idle until engine
is warm.
4. Click A/C switch from OFF to ON for 1 second, then
back to OFF for 5 to 10 seconds. Repeat this step
ten times.
3.10.4
Air Conditioning Compressor Protection
The compressor is protected from excessively low and high pressures by two switches that shut down the compressor
to prevent damage to the system.
• The LOW PRESSURE switch opens when the pressure falls to 2–8 psi (14–55 kPa), and shuts down the
compressor. When the pressure rises to 15–25 psi (103–172 kPa), the switch closes, and allows the compressor
to run.
• The HIGH PRESSURE switch opens and stops the compressor when the pressure rises to 315–335 psi
(2172–2310 kPa). When the pressure falls to 220–280 psi (1517–1930 kPa), the switch closes and allows the
compressor to run.
If the air conditioning system is shut down by either switch, locate the source of the problem, and correct it before
operating the system.
169890
48
Revision A
Summary of Contents for M105
Page 8: ......
Page 28: ...SAFETY Figure 1 21 Safety Signs LH Side 169890 14 Revision A ...
Page 30: ...SAFETY Figure 1 23 Safety Signs RH Side 169890 16 Revision A ...
Page 40: ......
Page 87: ...OPERATOR S STATION 169890 73 Revision A ...
Page 88: ...OPERATOR S STATION 169890 74 Revision A ...
Page 89: ...OPERATOR S STATION 169890 75 Revision A ...
Page 90: ...OPERATOR S STATION 169890 76 Revision A ...
Page 91: ...OPERATOR S STATION 169890 77 Revision A ...
Page 92: ...OPERATOR S STATION Operating Information Screens 169890 78 Revision A ...
Page 94: ......
Page 299: ...MAINTENANCE AND SERVICING Fuse Box Decal Figure 5 169 Fuse Decal 169890 285 Revision A ...
Page 350: ......
Page 372: ......
Page 382: ......
Page 383: ......