214685
285
Revision A
Figure 7.292: John Deere S7 Display
–
Checking
Sensor Voltage
8.
Select SENSOR tab (A) to view sensor voltages. The
center header height sensor voltage (B) must be
between 0.5 and 4.5 V, with at least 3 V of variation
between 0 and 4 on the float indicator box.
NOTE:
If the optional Auto Lateral Tilt AHHC kit is installed, the
left and right header height sensors must also be in the
same 0.5
–
4.5 V range.
9.
If sensor voltage adjustment is required, refer to
Adjusting Voltage Limits: One-Sensor System, page
162
Calibrating Feeder House (John Deere S7 Series)
Feeder house calibration must be done before header calibration.
For best performance of auto header height control (AHHC), perform these procedures with center-link set to
D
.
When setup and calibration are complete, adjust center-link back to desired header angle. For instructions, refer to
the header operator
’
s manual.
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator
’
s manual for updates.
1.
Ensure center-link is set to
D
.
2.
Rest header on down stops and unlock float.
3.
Place wings in locked position.
Figure 7.293: John Deere S7 Display
–
Harvesting Page
4.
On the HARVESTING page, select MENU icon (A) in
the bottom right corner of screen. The MENU opens.
Summary of Contents for FlexDraper FD1 Series
Page 2: ...FD1 Series FlexDraper Header Published June 2018...
Page 12: ......
Page 42: ......
Page 45: ...214685 33 Revision A Figure 4 6 Filler Cap 10 Install filler cap A SETTING UP FLOAT MODULE...
Page 72: ......
Page 116: ......
Page 166: ......
Page 336: ......
Page 350: ......
Page 353: ......