3.8.5
Gleaner R65/R66/R75/R76 and S Series Combines
Checking Voltage Range from the Combine Cab (Gleaner R65/R66/R75/R76 and S Series)
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to
the combine operator’s manual for updates.
1. Position the header 6 in. (150 mm) above the ground, and unlock the
fl
oat module
fl
oat.
2. Check that
fl
oat lock linkage is on down stops
(washer [A] cannot be moved) at both locations.
NOTE:
If the header is not on down stops during the next
two steps, the voltage may go out of range during
operation causing a malfunction of the AHHC system.
Figure 3.186: Float Lock
3. Ensure pointer (A) on the
fl
oat indicator box is on 0.
If necessary, adjust the cable take-up bracket (B) until
pointer is on 0.
Figure 3.187: Float Indicator box
147831
132
Revision A