![MacDon FD75 Operator'S Manual Download Page 241](http://html.mh-extra.com/html/macdon/fd75/fd75_operators-manual_685691241.webp)
214323
223
Revision B
4.14.4
Adjusting Threshold for Drop Rate Valve
This procedure explains how to adjust the point at which the restrictor valve opens, allowing full flow to the lift cylinders.
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to combine
operator
’
s manual for updates.
1003641
A
B
C
D
E
Figure 4.184: John Deere Combine Display
1.
Press DIAGNOSTIC button (A) on the monitor. dIA appears
on the monitor.
2.
Press UP button (B) until EO1 appears on the monitor and
press ENTER (C). This is the header adjustment.
3.
Press UP (B) or DOWN (E) button until 114 is displayed on
the top portion of the monitor. This is the setting that
controls when the fast drop rate starts with respect to the
dead band.
NOTE:
The default setting is 100. The ideal operating range is
typically between 60 and 85.
4.
Press ENTER (C) to select 114 as the fast drop rate (this will
allow you to change the first digit of the number sequence).
5.
Press UP (B) or DOWN (E) until the desired number is
displayed, then press CAL button (D). This will bring you to
the second digit. Repeat this procedure until the desired
setting is achieved.
6.
Press ENTER (C) to save the changes.
4.14.5
Operating Auto Header Height
To operate your auto header height, follow the steps in this procedure.
1015233
A
Figure 4.185: Accumulator Shut-off
IMPORTANT:
For proper performance, deactivate accumulator (A) as described
in the combine
’
s operator
’
s manual.