215626
53
Revision A
$
%
$
Figure 2.96: Overflow Hoses
4.
Attach the extension hose to the union fitting using the
larger gear clamp.
5.
Route hose (A) through the slot in the frame member and
secure it with cable tie (B) as shown.
6.
Trim hose (A) to length as follows:
•
R Series Rotary Disc Header:
Leave approximately
180 mm (7 in.) of free hose below the windrower frame.
•
A Series Auger and D Series Draper Header:
Leave
approximately 360 mm (14 in.) of free hose below the
windrower frame.
2.9.3
Installing Tank Overflow Hose Extension: M200 with Cat Engine
The hydraulic tank overflow extension is integrated into the fuel/hydraulic breather system on M200 windrowers with Cat
engines.
$
%
&
Figure 2.97: Overflow Hose
1.
Locate hydraulic and fuel tank breather hose (A).
2.
Connect supplied extension hose (B) to existing hose (A)
using a straight plastic joiner and two hose clamps at
location (C) as shown.
3.
Trim hose (B) to length as follows:
•
R Series Rotary Disc Header:
leave approximately 180
mm (7 in.) of free hose below the windrower frame.
•
A Series Auger and D Series Draper Header:
leave
approximately 360 mm (14 in.) of free hose below the
windrower frame.