To route hoses on early-build 2015, 2014 and earlier A40-D
Headers for use on M100, M105, and M205 Windrowers,
proceed as follows.
3.
Disconnect hoses as follows:
a.
Disconnect hose (A) from tee (C).
b.
Disconnect hose (B) from reel motor upper port.
c.
Disconnect tee (C) from reel motor lower port.
4.
Reconnect hoses as follows:
a.
Relocate tee (C) to reel motor upper port.
b.
Connect hose (B) to tee (C).
c.
Connect hose (A) to reel motor lower port.
Figure 3.139: Early-Build 2015, 2014 and Earlier
Factory Configuration (M150, M155, and M200)
Figure 3.140: Adjusted Configuration (M100,
M105, and M205)
5.
Close driveline shield before engaging header.
Figure 3.141: Driveline Shield
147913