Summary of Contents for 04-391-001

Page 1: ...INSTRUCTION MANUAL 04 391 001 Please read this instruction manual completely before operating this unit English Spanish Premium Digital Blood Pressure Arm Monitor Semi Automatic ...

Page 2: ...onal injuries whether to purchaser or others MABIS shall in no event be liable to the purchaser for any amount in excess of the cost of repair and or replacement of the unit or the purchase price of the unit Some states do not allow the exclusive or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rig...

Page 3: ...ls of the blood vessels throughout your body Your heart which is the center of the circulatory system provides the force for the blood to flow or circulate When your heart contracts or beats the blood is forced through the blood vessels increasing the pressure This is the highest pressure in the cycle or what is referred to as SYSTOLIC blood pressure In between beats your heart relaxes and your bl...

Page 4: ...ysiological characteristics 10 This device is intended for adult use 11 The inflation or deflation process can be stopped by pressing the Release button 7 Blood pressure is measured in millimeters mm of mercury Hg and is generally recorded with the systolic pressure 120 listed first and the diastolic pressure 80 listed second The numbers are typically separated by a slash mark as shown Both pressu...

Page 5: ...appear on the display Fig 1 NOTE Please consult with your physician or trained healthcare professional for further information regarding an irregular heartbeat and if this symbol appears frequently at the end of a reading Stage 3 Hypertension Systolic pressure 180 mmHg or Diastolic pressure 110 mmHg Stage 2 Hypertension Systolic pressure 160 179 mmHg or Diastolic pressure 100 109 mmHg Stage 1 Hype...

Page 6: ...tment matching the indicated polarity symbols Fig 1 3 To close match up and connect the bottom hooks of the cover then push the top end NOTE Replace the batteries when the Low Battery symbol appears on the display or when the display remains blank when the POWER button is pressed 4 It is recommended to remove the batteries if the unit will not be used for an extended period of time AC Power Adapte...

Page 7: ... range A different sized cuff is needed if the Index mark is outside of the OK range Taking Your Blood Pressure Reading Proceed only after reading the previous sections of this manual 1 Position the monitor on a flat stable surface with the digital display panel in view Insert the cuff tubing connector into the left side of the monitor Fig 1 2 Rest your elbow on a solid surface with your palm faci...

Page 8: ...he saved measurements After youʼve scrolled through all the readings the unit will automatically turn off NOTE When the number of readings exceeds 60 the oldest data will be replaced with the new record To erase all stored measurements 1 Press and release the MEMORY button The unit will display how many measurements are stored within the bank 2 Press and hold down the MEMORY button until two horiz...

Page 9: ...tic Premium Digital Blood Pressure Arm Monitor 04 391 001 Display system Digital display LCD Measuring method Oscillometric Power source 4 AA batteries Measuring range Pressure 0 300 mmHg Pulse 30 180 beats minute Accuracy Pressure 3 mmHg Pulse 5 of reading Inflation Manual Inflation Deflation Automatic Pressure Release Valve Manual fast release Memory Built in memory enabling display of up to 60 ...

Page 10: ...Blood Pressure Log Name Age Weight Date Time 240 220 200 180 160 140 120 100 80 60 Pulse Body Con dition mmHg 18 ...