background image

1

owner's manual

window type air conditioner

model
MEE09VV

read this manual before installing your new air conditioner

PM01

Summary of Contents for MEE09VV

Page 1: ...1 owner s manual window type air conditioner model MEE09VV read this manual before installing your new air conditioner PM01...

Page 2: ...2...

Page 3: ...is product as unsorted munici pal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal th...

Page 4: ...void a hazard Do not modify power cord length or share the outlet with other appliances It may cause electric shock or fire due to heat generation Do not operate the unit with wet hands or in damp env...

Page 5: ...it to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc Stop operation and close the window before a storm or hurri cane Operation with windows open...

Page 6: ...rotection The specifications of the fuse are printed on the circuit board such as T 3 15 A 250 V etc Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do n...

Page 7: ...use water to clean the interior of the air conditioner Expo sure to water can destroy the insulation leading to possible elec tric shock When cleaning and maintenance the unit first make sure that th...

Page 8: ...ly grounded The wall outlet air break switch should be provided with a reliable ground wire The unit should be provided with an individual circuit and the cir cuit breaker fuse rating should be the sa...

Page 9: ...me The follow ing illustration is for explanation purpose only the actual shape of the machine you purchased may be slightly different 8 7 6 3 2 1 1 2 3 3 5 6 7 8 9 Model A Front panel Air filter Fram...

Page 10: ...model you purchased All the illustrations in the manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail Seal optional Used on drain join...

Page 11: ...pull the lever toward you To close the vent push it in To open the vent set the lever to the right position To close it set the lever to the left position operation instructions control panel LOW MOD...

Page 12: ...wing feature The indicator light next to the SWING keypad will illuminate identi fying the selected mode The vertical louvers will oscillate back and forth side to side automatically sweeping air alte...

Page 13: ...onds it shows the room temperature on some models or the set temperature on some models Error codes on some models Eo Indicates a malfunction of the outdoor condenser temperature sensor When one of th...

Page 14: ...you will require two AAA 1 5 Volt batteries included Batteries should be replaced when No signal beep is heard from the main unit when initiating pro gram commands from the remote control The main uni...

Page 15: ...select either COOLING FAN or DRY mode Set AUTO temperature on some models Press the TEMP UP DOWN pads to select increase decrease the de sired operating temperature The selected temperature will appea...

Page 16: ...e at the maximum upwards or downwards angle position for a long time in cooling or drying mode air filter The air filter behind the inlet grille should be checked and cleaned at least once every 2 wee...

Page 17: ...brush to clean the front panel as this will damage the surface of the part winter storage If you plan to store the air conditioner during the winter remove it carefully from the window according to th...

Page 18: ...essories bag 3 Fix the drain tray onto the bottom of cabinet using the screws 4 Connect an extension drain hose locally purchased to the outlet of drain tray Bottom drain hole Rubber plug Rubber plug...

Page 19: ...d vibration and noise make sure the unit is installed se curely and firmly 2 Install the unit where the sunlight does not shine directly on the unit If the unit receives direct sunlight build an awnin...

Page 20: ...lope down towards the rear by about 5 mm to allow wa ter generated during operation to drain Step 3 Install the housing into the wall and secure Make sure the foam seals are not damaged Flash seal or...

Page 21: ...on instruction 5 Switch unit on Check for operation of the unit and check for vi bration in the installation 6 Fit the drain pan to the housing and run a drain line to a suitable location if required...

Page 22: ...er there are four kinds of removing the frame Remove the two screws on the left and right chassis fixing brackets Then remove the two chassis fixing brackets as shown in Fig 3A Remove one screw on the...

Page 23: ...he cabinet See Fig 6 3 Push the unit chassis into the cabinet See Fig 7 Fig 9 Fig 8 Step 4 Install the frame 1 Install the frame and connect the coupler plugs making sure not to interfere with the tem...

Page 24: ...rainy days The water may overflow and drip from the outdoor side of the unit The fan may continue to operate when the compressor has cycled off What to do The air conditioner is unplugged Air conditio...

Page 25: ...tions section Ambient temperature is high When the air condi tioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers and...

Page 26: ...h Model Note D value is for reference only Minimum nominal cross section area of conductors Rated current of appliance A Nominal cross section area 3 y 6 6 y 10 10 y 16 16 y 25 0 75 mm 1 mm 1 5 mm 2 5...

Page 27: ...27...

Page 28: ...28...

Reviews: