When utilising the cardan shaft, observe any instructions provided by the shaft's manufacturer. The
splitter requires at least 7.5 kW of power (10 kW for the Easy model), which must be taken into account
with regard to the capacity of the cardan shaft. A suitable shaft would be, for example, B1080CEACOA60.
Check that the shaft is properly locked to the splined shaft of the angle transmission! The chain that
prevents the guard from rotating must be attached to point C of the angle transmission's base. Never use
a damaged or unprotected cardan shaft.
Note! Tractor-powered splitters must be attached to the tractor's lifting equipment.
4.2 Electrical drive
An
electrically-powered
splitter
requires 7.5 kW of power for the basic
model and 10 kW for the Easy model.
The fuse must be at least 20 A in the
basic model and 25 A in the Easy
model. The electrical cable must be at
least 5 x 2.5 mm² (7.5 kW) or 5 x 4
mm² (10 kW). In order to connect the
cable, move the protective cover B of
the electrical connector A and angle
transmission into a position where it
covers the angle transmission.
To start the splitter, use the starter
located on the front side of the
machine where the operator stands
(Note! In the Easy model, the starter is
on the right side of the control panel).
If the electric motor rotates in the
wrong direction (i.e. the machine
makes an abnormal noise and the
hydraulic functions are inoperable),
the current phase is incorrect. We
recommend using an extension cord
that allows you to switch the current
phase.
Note! If the extension cord does not
have a phase switch, the electrical
work related to changing the phase
must be performed by an electrician.
Figure 22. Powering the machine with electricity
Figure 23. Starter