Exit time 

(in seconds) 

 the time interval from the physical arming from a user and the arming of the 

alarm panel. You can choose when the Exit time will be applied 

 when arming from a wireless 

keyfob, in case of remote arming from the mobile application or both.

 

 

• 

Alarm cycle duration 

(in seconds) 

 the time interval when the siren will be active after an alarm 

event

 

 

• 

Enable sound indication 

from the siren when the alarm panel is armed and disarmed 

• 

Sound indication from the siren 

in case of tamper alarm

 

 

Configuring the zones  

 The RControl RF Alarm supports up to 8 wired and up to 32 wireless zones. If you need to change the 

default self-

learning behavior, you can configure the zones from the “RControl Alarm” menu, section 

“Zones”

 

for the wired zones or “RF Zones” 

for the wireless zones.  

 With a double click on the selected zone you can:  

• 

Change the name of the zone 

 

from section “Zone name” 

 

• 

Enable or Disable the zone 

 

from section “Enabled” 

 

• 

Set the type of the zone 

 Instant, Entry/Exit, Follow, Tamper, Panic, Fire and etc. 

 from the menu 

“Zone type”. Select “Disabled” if the zone will not be used 

 

• 

If you have configured a zone as a “Keyswitch zone” 

you can choose if the alarm panel would be 

Armed/Disarmed when this zone is activated. 

This can be configured fr

om the menu “Keyswitch 

action” 

 

• 

Configure zone arming type = “Full arm” and “Stay arm” –

 

from menu “Keyswitch arming”. 

 

• 

Choose if the siren will be activated when the zone is violated 

 

from section “Notification type” 

 

• 

Can choose if every violation of the zone will be reported during the alarm cycle time. You can 
configure this from section 

“Report All During Alarm Cycle”. 

 

If this setting is disabled only the initial violation will be reported and all following activations will 
not be reported until the alarm cycle time expires. When the alarm cycle time expires, the zone 
restore event will be reported only when the zone is really restored. In addition, even when there 
was a restore during the alarm cycle, this restore will not be reported until the expiration of the 
alarm cycle time or until the partition is disarmed.  

Zone types  

• 

Smart Enroll

 

 by default all zones are configured as 

Smart Enroll

 zones. This means that the 

detectors added on these zones will be automatically registered (self-learned) as Instant zones. If 
you want to configure different zone type you can do that from the RControl Admin portal > Device 
Dashboard > RControl Alarm Settings.  

• 

Entry/Exit zone

 

 The Entry/Exit zones can be violated during the entry/exit time delay without 

causing an alarm event.  

If an Entry/Exit zone is violated while the system is armed, the alarm panel will start counting the 

entry time. If the system is not disarmed during the entry time an alarm event is generated.  

NOTE! If the entry/exit time is 0 sec, the Entry/Exit zone works as an Instant zone.  

  

• 

Follow zone - 

This zone can be violated during the entry/exit delay time without generating an 

alarm event. If the zone is violated while the panel is armed, the panel immediately generates an 

alarm event (without counting entry time).  It is called “Follow” zone because it depends on the 

Entry/Exit zone. If the Follow zone is violated after an Entry/Exit zone has also been violated then 
the alarm panel will wait until the entry time passes before generating an alarm event.  

Summary of Contents for RControl MQ03SD-RCALARM-RF

Page 1: ...r building M8 Sofia 1309 Bulgaria Web Site www m2mservices com M2M Services Ltd RControl Alarm MQ03SD RCALARM RF Installer s Manual V 1 6 M2M Services Ltd 1 Kukush Str building M8 Sofia 1309 Bulgaria...

Page 2: ...Wired and wireless detectors 5 Adding wired detectors 5 Pairing a wireless detector 5 Pairing wireless panic button 6 Disabling a wireless sensor 7 Deleting all keyfobs and wireless detectors 7 Keypad...

Page 3: ...process in the most commonly used scenario when only instant zones with no entry exit times are needed By default all wired zones of the alarm panel are initially set to SMART Enroll type When a new...

Page 4: ...which will not allow you to pair the next keyfobs before you disarm the panel The learning mode lasts 10 seconds If the receiver does not receive signal from the keyfob in the timeframe of 10 seconds...

Page 5: ...automatically receive labels Keyfob 101 Keyfob 116 These labels appears in the mobile application when arming disarming with keyfob You can change the keyfob labelling anytime from the RControl Admin...

Page 6: ...nitializes wait for the LED to stop blinking Enter in learning mode press the white button on the RF receiver Activate the sensor twice by moving in front of the sensor activate the sensor once and wa...

Page 7: ...of the alarm panel supports 1404RKZ and 1555RKZ DSC keypads The keypad should be powered from AUX and AUX Connect terminal R RED of the keypad to AUX of the alarm panel Connect terminal B BLK of the k...

Page 8: ...Account No 0000 Periodical tests interval in this field you can configure the interval for the periodical test messages in seconds that the alarm panel will send NOTE This interval is different from...

Page 9: ...le time You can configure this from section Report All During Alarm Cycle If this setting is disabled only the initial violation will be reported and all following activations will not be reported unt...

Page 10: ...configuring a 24h Panic zone of the panel you can also use the built in panic button of the wireless keyfob For firmware versions higher than 6 5 22 it is disabled by default You can enable the panic...

Reviews: