Remote Arming/Disarming via the RControl Application
To enable the remote control via the mobile application, go to Menu > Settings > Remote Arming/Disarming
and enable the Arming/Disarming feature.
Ask the end user to enter a Remote PIN code of their choice and Disarm (or Arm) from a keyfob or the
keypad within 2 minutes to complete the initial pairing procedure.
Changing the default keypad user code
The end user can change his keypad user code from the mobile application.
To change the code go to Menu > Settings > Remote Arming/Disarming > Change Remote PIN.
Configuring the RControl Alarm
In general, the alarm panels are preconfigured with a template according to the needs of each customer.
If any changes to the basic configurations are needed you can apply them from the RControl Admin
Portal
https://www.m2mservices.com/admin
by logging with your administrative credentials.
You can find the alarm panel by its serial number or by account number, IMEI, etc.
Select the RControl Alarm System,
press the right button and choose “RControl Alarm”
menu.
General settings of RControl Alarm
•
Account Number
–
in the field “Account No” you must fill the number with which the panel will
report to the central monitoring station. The Account No. must be 4-digits long. By default the alarm
panel is configured to report with Account No. “0000”
•
Periodical tests interval
–
in this field you can configure the interval for the periodical test messages
(in seconds), that the alarm panel will send.
•
NOTE:
This interval is different from the interval configured for the supervision of the GPRS
connection
–
the “heartbeat interval”. The connection is supervised on every 10 minutes by default
whereas the periodical tests are usually sent every couple of hours (e.g. 12 or 24 hours).
•
Configuring a delay in case of mains power outage
–
in the field “Delay”, section “Main Power” you
can configure the delay (in seconds) after which the device will report the mains power outage.
•
Configuring the Battery level thresholds -
In section ”Battery”, field “Battery low” you can set a low
voltage threshold, under which the alarm panel will send “Low Battery” event. In the filed “Battery
Critical Low” you can set even lower voltage threshold and if the battery voltage goes u
nder this
level, it will be considered as critically low.
In order to preserve the battery from permanent damage, you can configure the panel to shut down
automatically if the voltage of the battery drops under the critically low threshold. You can enable that
feature by checking the “Auto shutdown when battery critical low” checkbox.
Configuring the partition
The RControl RF Alarm panel supports 2 Partitions.
•
You can configure different Partition settings from RControl Alarm menu, section “Partitions”:
•
Partition name
–
the name which would be visible in the mobile application.
•
Entry time
(in seconds)