Remote Arming/Disarming via the RControl Application 

To enable the remote control via the mobile application, go to Menu > Settings > Remote Arming/Disarming 

and enable the Arming/Disarming feature. 

Ask the end user to enter a Remote PIN code of their choice and Disarm (or Arm) from a keyfob or the 

keypad within 2 minutes to complete the initial pairing procedure. 

Changing the default keypad user code 

The end user can change his keypad user code from the mobile application. 

To change the code go to Menu > Settings > Remote Arming/Disarming > Change Remote PIN. 

 

 

Configuring the RControl Alarm  

In general, the alarm panels are preconfigured with a template according to the needs of each customer. 

If any changes to the basic configurations are needed you can apply them from the RControl Admin 
Portal 

https://www.m2mservices.com/admin

 by logging with your administrative credentials.  

You can find the alarm panel by its serial number or by account number, IMEI, etc.  
Select the RControl Alarm System, 

press the right button and choose “RControl Alarm” 

menu. 

 

General settings of RControl Alarm  

• 

Account Number

 

 

in the field “Account No” you must fill the number with which the panel will 

report to the central monitoring station. The Account No. must be 4-digits long. By default the alarm 

panel is configured to report with Account No. “0000” 

 

• 

Periodical tests interval

 

 in this field you can configure the interval for the periodical test messages 

(in seconds), that the alarm panel will send.  

• 

NOTE:

 This interval is different from the interval configured for the supervision of the GPRS 

connection 

 

the “heartbeat interval”. The connection is supervised on every 10 minutes by default 

whereas the periodical tests are usually sent every couple of hours (e.g. 12 or 24 hours).   

• 

Configuring a delay in case of mains power outage

 

 

in the field “Delay”, section “Main Power” you 

can configure the delay (in seconds) after which the device will report the mains power outage.  

• 

Configuring the Battery level thresholds -

 

In section ”Battery”, field “Battery low” you can set a low 

voltage threshold, under which the alarm panel will send “Low Battery” event. In the filed “Battery 
Critical Low” you can set even lower voltage threshold and if the battery voltage goes u

nder this 

level, it will be considered as critically low.  
  

In order to preserve the battery from permanent damage, you can configure the panel to shut down 

automatically if the voltage of the battery drops under the critically low threshold. You can enable that 

feature by checking the “Auto shutdown when battery critical low” checkbox. 

 

Configuring the partition  

The RControl RF Alarm panel supports 2 Partitions.  

• 

You can configure different Partition settings from RControl Alarm menu, section “Partitions”: 

 

• 

Partition name 

 

the name which would be visible in the mobile application.

 

 

• 

Entry time 

(in seconds) 

 

 

Summary of Contents for RControl MQ03SD-RCALARM-RF

Page 1: ...r building M8 Sofia 1309 Bulgaria Web Site www m2mservices com M2M Services Ltd RControl Alarm MQ03SD RCALARM RF Installer s Manual V 1 6 M2M Services Ltd 1 Kukush Str building M8 Sofia 1309 Bulgaria...

Page 2: ...Wired and wireless detectors 5 Adding wired detectors 5 Pairing a wireless detector 5 Pairing wireless panic button 6 Disabling a wireless sensor 7 Deleting all keyfobs and wireless detectors 7 Keypad...

Page 3: ...process in the most commonly used scenario when only instant zones with no entry exit times are needed By default all wired zones of the alarm panel are initially set to SMART Enroll type When a new...

Page 4: ...which will not allow you to pair the next keyfobs before you disarm the panel The learning mode lasts 10 seconds If the receiver does not receive signal from the keyfob in the timeframe of 10 seconds...

Page 5: ...automatically receive labels Keyfob 101 Keyfob 116 These labels appears in the mobile application when arming disarming with keyfob You can change the keyfob labelling anytime from the RControl Admin...

Page 6: ...nitializes wait for the LED to stop blinking Enter in learning mode press the white button on the RF receiver Activate the sensor twice by moving in front of the sensor activate the sensor once and wa...

Page 7: ...of the alarm panel supports 1404RKZ and 1555RKZ DSC keypads The keypad should be powered from AUX and AUX Connect terminal R RED of the keypad to AUX of the alarm panel Connect terminal B BLK of the k...

Page 8: ...Account No 0000 Periodical tests interval in this field you can configure the interval for the periodical test messages in seconds that the alarm panel will send NOTE This interval is different from...

Page 9: ...le time You can configure this from section Report All During Alarm Cycle If this setting is disabled only the initial violation will be reported and all following activations will not be reported unt...

Page 10: ...configuring a 24h Panic zone of the panel you can also use the built in panic button of the wireless keyfob For firmware versions higher than 6 5 22 it is disabled by default You can enable the panic...

Reviews: