Wireless keyfobs
Supported functions
The wireless keyfobs have 4 buttons - Full Arm, Home Arm, Disarm and Panic. By default, only the Full
Arm and Disarm buttons are active.
To enable the Home Arm button, you need to have at least one STAY zone. Please refer to the
“Configuring the zones” section.
To enable the Panic buttons of the keyfobs
, please refer to the “Configuring the panic button” section.
Pairing a wireless keyfob
The RControl Alarm panel supports up to 16 wireless keyfobs. 2 keyfobs are included in the standard kit
and they are already paired.
To use additional keyfobs you should first pair them with the alarm panel.
Note: To be able to enter into learning mode, make sure that the panel is DISARMED!
To enter into learning mode, press the white button of the RF receiver of the panel. The red LED
indicator of the RF receiver will turn ON. After this LED indication, press any button of the wireless
keyfob
(hold the button at least 1 sec)
. The siren will beep once, which indicates that the keyfob was
paired and the procedure was successfully completed.
Note:
It’s recommended to pair the keyfob with Disarm button. That way you will not arm the panel by
mistake which will not allow you to pair the next keyfobs before you disarm the panel.
The learning mode lasts 10 seconds. If the receiver does not receive signal from the keyfob in the
timeframe of 10 seconds, the pairing procedure will be terminated. The siren will beep 4 times to
indicate an error.
When a new keyfob is paired, the panel reports an event “Access Granted, User N” with ContactID E
-
422. Each keyfob reports with different user number.
You need to repeat the pairing procedure for each additional keyfob.
Note:
To allow the panic button on the keyfob please refer to section
“Configuring the panic button”
Assigning a keyfob to different partition
By default the keyfob controls the first partition after the pairing procedure. If there is a more than one
partition set you can set the keyfob to control a particular partition. To do that log in the RControl
Admin Portal, navigate to RControl Alarm menu, section Keyfobs and choose the desired Partition for
each keyfob.
Note:
By default, each keyfob controls only one partition. If you want to control both partitions with a
single keyfob, choose Partition=All for that particular keyfob in the RControl Admin portal. The buttons
of the keyfob from the upper row will control Partition 1, the buttons from the lower row will control
Partition 2. You will not be able to use Home Arm and Panic features of that keyfob.