background image

MiNi01-4G 

Cellular Communicator with Dial Capture interface 

Quick Installation Manual 

Connecting the communicator to the alarm panel 

(+)          12VDC Power Supply 

(-)           Ground    

Green:   RING 

Yellow:  TIP 

White:   IN1     (for the optional remote Arming/Disarming feature) 

Orange: OUT1 

(for the optional remote Arming/Disarming feature) 

 

WARNING: The wiring should be done only when the panel and the  
communicator are disconnected from the powerline! 

 

Connect the RING and TIP of the alarm panel to the RING and TIP of the unit 

 

WARNING: Primary use only – NOT to be used with landline!  
Having a phone line connected will damage the unit! 

 

Connect the antenna and place it outside of the alarm panel’s box 

 

C and – of the communicator to 12V-15V DC power supply 

LED Indicator 

 

Slow flashing – trying to establish connection 

 

Constantly On – connection established at good signal level 

 

Constantly On, blinking every 5 sec – connection established at low signal level 

 

Fast flashing – transferring data 

Configuring the alarm panel 

Refer to the panel’s installer manual to configure the following options: 

 

Enable the PSTN dialer of the panel 

 

Select DTMF mode (Tone dialing) 

 

Select Contact ID Full communication format 

 

Enter a telephone number for dialing (you can use any number, e.g. 9999999) 

 

Enter a 4-digit account number in the panel.  

Configuration guides for popular panels are available at 

www.MiNi01-4G.com

  

Troubleshooting the DTMF communication  

If you have issues receiving the events, try the following additional settings of the panel: 

 

Disable “Telephone line monitoring” 

 

Disable “Wait for dial tone” option 

 

Use “A” instead of “0” in the account number 

 

If there is more than one partition, enter an account number for each partition 

 

For certain panels, you might need also to specify an account number for the main 
partition 0 (sometimes referred as system number) 