M2I TOPRT-Ex Series Hardware Manual Download Page 3

Industrial HMI Touch Panel Hardware Manual       

 

M

2

I Corporation                                                                                                                                                               3 / 23 

11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,   
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr

 

Chapter 1 Safety Precautions 

 

■  Before using the product 
To use the product safely and effectively, please read the contents of this manual thoroughly before use. Please 
keep to the safety precaution, for it is to prevent accidents and potential danger from occurring. Safety precaution 
is classified into ‘Warning’ and ‘Caution’ and their meanings are as follows

Also the indicated illustrations on the 

product and in the manual have the following meanings. 
 

 

Violating the instruction may result in serious personal injury or death. 

 

Violating the instruction may result in slight personal injury or product damage. 

 

Be cautious, for danger may be present. 

 

Be cautious, for there is a possibility of an electric shock. 

 
■  Anti-Explosion Precautions 

Do not open the product when explosive gas is around. 
All cables connected with the product should not be connected or disconnected when the power of product 
is on. 

        Do not change SD Card when the power is connected to product. 
 
■  General Precautions 

Do not press the screen with a hard or sharp object (awl, screwdriver, pen) with too strong a force.   
It may cause malfunction of touch due to damage of the front sheet. 
Do not use or store in an environment with high vibration. 
Do not allow foreign objects such as water, liquids, or metal powders to enter the product. This may cause 
breakage or electric shock. 
Use the radio or mobile phone at least 30cm away from the main unit. 
Two or fewer bright spots may appear on the LCD screen, and certain areas may appear brighter, but this is 
not a defect in LCD characteristics. 
Do not store or operate in direct sunlight. Direct sunlight can change the properties of the LCD. 

 
■  Design Precautions 

Install protection circuit on the outside of Products to protect the entire control system when external power 
supply or Products have problems. 
As the malfunction & incorrect result of Products could damage the stability of the entire systems and human 
body,  you  must  install  damage  preventing  interlock  circuit  such  as  emergency  stop,  Protective  circuits, 
positioning upper and lower limit switch and interlock for forward/reverse operation. 
When a computer or other controllers communicate and exchange data with products or change operation 
mode  of  products,  set  up  protective  sequence  program  in  PC  or  Controller  for  protecting  system  from 
communication error. 
The output signal or communication lines should be separated from the power line or high tension wire.   
They should be installed 100mm (3.94 Inch) or more from each other. 

Summary of Contents for TOPRT-Ex Series

Page 1: ...5 Korea Tel 82 70 465 3366 Fax 82 31 465 3355 www m2i co kr Thank you for purchasing the industrial HMI touch panel series of M2I corporation Please read this manual carefully to know installing wirin...

Page 2: ...1 TOPRT1210SD Ex 8 4 2 TOPRT1230XD Ex TOPRT1240XD Ex 9 4 3 TOPRT12 Ex Series Rear Part Names and Specifications 11 4 4 TOPRT12 Ex Series Side Part Names and Specifications 11 4 5 TOPRT12 Ex Series To...

Page 3: ...n with too strong a force It may cause malfunction of touch due to damage of the front sheet Do not use or store in an environment with high vibration Do not allow foreign objects such as water liquid...

Page 4: ...low should be avoided Do not Install product to the place which the ambient temperature is out of limits from 10 to 50 or on the surface of control board which high pressure equipment is installed Do...

Page 5: ...d It is a device based on RS 232C and RS 422 485 Ethernet which is used for the basic purpose of communication with another device PLC 2 2 Package Contents The components of the product are as follows...

Page 6: ...EX model of 1210 has S for XGA TOPRT1210SD Ex is combined by TOPRP10D and TOPRD1220X 2 3 1 Process Module Main Unit TOPR P Series Type Option Power P Process 10 Standard D DC T P D 50 Standard 10 Per...

Page 7: ...ls only Part Specification Model Front Camera Built in Resolution VGA 640 480 TOPRT 10 30 40 Proximity Sensor Built in Sensing Distance 0 7M TOPRT 10 30 40 Brightness Sensor Built in Brightness contro...

Page 8: ...aero 327beon gil Dongan gu Anyang si Gyeonggi do 14055 Korea Tel 82 70 465 3366 Fax 82 31 465 3355 www m2i co kr Chapter 4 Part Names and General Specifications 4 1 TOPRT1210SD Ex 4 1 1 TOPRT1210SD Ex...

Page 9: ...tion Support Model Power LED System Power Status LED Common Proximity Sensor Automatically backlight ON OFF by sensing object coming Option Brightness Sensor Automatically brightness controls by ambie...

Page 10: ...1240XD Ex Front Part Names and Specifications No Part Description Support Model Power LED System power status LED Common Proximity Sensor Automatically backlight ON OFF by sensing object coming Common...

Page 11: ...x Series Side Part Names and Specifications 4 5 TOPRT12 Ex Series Top Part Names and Specifications No Part Form Description Etc External antenna connector SMA FEMALE External antenna connector Option...

Page 12: ...ernal Device Interface In order for the main unit to communicate with an external device please check below contents 5 1 Serial Interface 5 1 1 RS 232C Items Contents Protocol Full Duplex Synch Asynch...

Page 13: ...d 4 RDB RD Input RS 422 485 Data Receive 5 SG Signal Ground 6 SDA SD Output RS 422 485 Data Send 7 RTS Output RS 232C Send Request Signal 8 CTS Input RS 232C Send Available Signal 9 SDB SD Output RS 4...

Page 14: ...ase of connected directly without HUB Cross Cable should be used Ex Cross Cable Wiring In the above wiring diagram TD and RD are changed and TD and RD are exchanged 5 3 USB Interface 5 3 1 USB Host Ty...

Page 15: ...y be changed or cause malfunction and damage 2 Be sure that heat from surrounding equipment does not cause product to exceed its standard operating temperature 3 In order to minimize external mechanic...

Page 16: ...nstructions to install the product 6 3 1 Direction It is recommended that the power connector at the rear is located at the top for vertical installation 1 TOPRT1210SD Ex 2 TOPRT1230XD Ex TOPRT1240XD...

Page 17: ...3 3 Fixation Installation methods should be following by using the supplied installation clamps for IP performance 1 Insert the clamp into the slot of the product 2 Screw the unit into the panel cut...

Page 18: ...vertically Close TOPRT1210XD Ex TOPRT1230 40 6 4 2 Data Upload and Download You can download or Upload Project file data by connecting USB cable TOPRT1210SD Ex TOPRT1230XD Ex TOPRT1240XD Ex Do not use...

Page 19: ...losion due to spark due to abnormal cable loss Therefore please be sure to familiarize yourself with how to use Pin Terminal ferrule below B L F E D d 1 8 2 0 22 18 12 14 5 3 3 3 8 2 2 5 3 Wiring of p...

Page 20: ...terminal block install the cable clamp to prevent the USB connection from being disconnected or sparking because the cable is disconnected 1 Place cable clamp at the screw hole on Rear of the product...

Page 21: ...atch or pollution by eye 8 3 Problems with the Device a If there is a problem during operation stop using it and contact the A S department of M2I which is indicated on the product label b Only the au...

Page 22: ...I Touch Panel Hardware Manual M2I Corporation 22 23 11 35 Simin daero 327beon gil Dongan gu Anyang si Gyeonggi do 14055 Korea Tel 82 70 465 3366 Fax 82 31 465 3355 www m2i co kr Chapter 9 Product and...

Page 23: ...o M2I Copyright M2I corporation 2023 09 www m2i co kr Document No TOPRT D0008 Rev 0 When using M2I equipment thoroughly read this datasheet and associated manuals introduced in this datasheet also pay...

Reviews: