Main Module Users Manual 

CTOP3M 

 

 

 
 
 
 

 

 

 

 

 

 

 

Copy Writer : M2I corporation   2008.05                      

M2I Corporation 

-

 

When  using  M2I  equipment,  thoroughly  read  this  datasheet  and  associated  manuals 
introduced in this datasheet, Also pay careful attention to safety and handle the 
module properly. 

-

 

Store this datasheet in a safe place so that you can take it out read it whenever 
necessary 

Summary of Contents for CTOP3M

Page 1: ...oration When using M2I equipment thoroughly read this datasheet and associated manuals introduced in this datasheet Also pay careful attention to safety and handle the module properly Store this datas...

Page 2: ...t out and read it whenever necessary Always forward it to the end user Installation Precautions Warning Caution Use the TOP in an environment that meets the general specification contained in this man...

Page 3: ...connected to output does NOT exceed the rating of output module Overcurrent exceeding the rating of output module could cause fire damage or erroneous operation Build a circuit that turns on the exter...

Page 4: ...ated 2 Power Cable Wiring Input DC Voltage Typically DC24V 20 28V Please be cautious wiring 24V and GND on power supply terminals Please separate power source cable from controller s power cable or in...

Page 5: ...ode Initial Screen Number Screen Save Buzzer Sound Start of Latch End of Latch Printer Security Password Touch Sensitivity In Case of System Error LCD Brightness Contrast Default Setting 4 Diagnosis F...

Page 6: ...such as conductive debris inside the module Conductive debris could cause fires damage or erroneous operation Completely turn off the external power supply when installing or placing wiring Not doing...

Page 7: ...the module Not doing so could cause failure or malfunction of the module Use a cellular phone or walky talky more than 30cm 11 81 inch away from the TOP Not doing so can cause a malfunction Do not str...

Page 8: ...S and Font download menu of TOP Designer on PC download them to TOP main module After finishing downloading TOP main module will be reset automatically When Font TOP will not be reset Method 2 OS DOW...

Page 9: ...Outer Dimension Front Rear Side Upper Bottom Fig Front Outer Dimension Fig Rear Outer Dimension...

Page 10: ...Fig Left Right Outer Dimension Fig Upper Bottom Outer Dimension Panel Cutting size 158 W 126 H mm...

Page 11: ...te 9600 19200 38400 57600 76800 115200bps Data Type Data Bit 7 8bit Parity Bit None Odd Even Parity Stop Bit 1 2bit Connector Pins and Signals Type Pin Number Signal Direction Contents 9 Pin Female CO...

Page 12: ...e of Connection 1 N N 31 Control Code ASCII Code or HEXA Code Baud Rate 9600 19200 38400 57600 76800 115200bps Data Type Data Bit 7 8bit Parity Bit None Odd Even Parity Stop Bit 1 2bit Connector Pins...

Page 13: ...cd 2 Touch Panel Analog 3 Front Sheet Front Vinyl Cover Sheet for Dampproof and Dustproof 4 Status LED Status of Power Fig 2 Rear View No Title Num of Pin Feature 1 Rubber Packing Shock Absorber for P...

Page 14: ...158 W X 126 H Mm General Specification Item Specification Input Voltage DC type DC 24V 20 28V Power Consumption 15W Input Power Cable AWG18 AWG26 Noise Immunity Impulse Noise 1000Vp p Pulse width 1 In...

Page 15: ...5 6 7 SG 8 20 Download Interface RS232C Download Connection RS232C In case of connecting Main Module 6P Connector and PC 9P Connector Main Module 6P Male PC 9P Female In case of connecting Main Modul...

Page 16: ...Head Office Kyonggi Venture Anyang Technical Center 13th Floor 572 5 Anyang 8 Dong Dongan Gu Anyang Si Kyonggi Do Korea 431 060 TEL 82 31 465 3366 FAX 82 31 465 3355 http www m2i co kr M2I Corporation...