Installation and Operating Parameters
Please refer to the appropriate product specification sheet for more information.
Tank Plate and Welding Flange
Parameter
Minimum
Maximum
Temperature
-80 °C
(-112 °F)
200 °C
(392 °F)
Pressure
-1 barg
(-14.5 psig)
10 barg
(145 psig)
Mixing Head, Male Bearing, and Tank Plate
Define the operating parameters inside the vessel. GMP Mixers are designed for non
explosive and non hazardous areas.
Parameter
Minimum
Maximum
Temperature
5 °C
(41 °F)
135 °C
(275 °F)
pH
1
14
Viscosity
1 cP
800 cP
Media
Media may not contain magnetic particles
Rotation speed
see Product Specification Sheet
Minimum acceleration and
deacceleration time
Five seconds (Specific to each application; set accordingly.
)
Drive Unit
Defines the operating parameters inside the vessel.
Parameter
Minimum
Maximum
Ambient temperature
0 °C (32 °F)
40 °C (104 °F)
Noise level and Vibrations
Noise levels are measured according to ISO
®
1680 standard, and are within maximum
levels specified by standards CEI 2–24/IEC 34–9. Vibration falls under standard class N
and is specified by standard CEI 2-23/IEC 34-14.