3. Remove the protective cap. Ensure that the thread connection in the tank plate and
male bearing are clean, dry, and free from foreign material.
1
2
4. Tighten the male bearing clockwise by hand into the thread of the tank plate, making
sure that it is aligned with the center line of the tank plate.
1
2
5. Position the male bearing in the appropriate tightening tool or multi-tool with a torque
wrench. Ensure that the tool fits the nut. Tighten the bearing to metal-to-metal
contact, applying torque according to table below.
Important: Ensure metal-to-metal contact by applying recommended torque in table
below. If bearing is not installed properly it may come off.
3
4
Catalog Number
Torque
GM05/23
6Nm/4.4Lbft
GM05/24
GM1/23
GM1/24
GM510/23
GM510/24
GM20/23
13Nm/9.6Lbft
GM20/24
GM50300/23
30Nm/22.1Lbft
GM50300/24
Mixing Head Installation
See NovAseptic
®
GMP Mixing Head Installation Guide 00101787PU for additional information.
• Handle the mixing head with care.
• Use extreme care when mounting the mixing head on to the male bearing; mixer
bearings are brittle.
• Do not mount the drive unit before installing the mixing head. The powerful
magnetic force between the mixing head and the outer drive head may cause severe
damage to bearings or personal injury.
!
NovAseptic
®
GMP Mixer Installation and User Guide
11