Phone: +81(6)6659-8201   Fax: +81(6)6659-8510   E-mail: [email protected]

RTD TRANSMITTER

MODEL

W2RS1

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Signal conditioner (body + base socket) ...................... (1)

 MODEL NO.

Confirm that the model number described on the product is 
exactly what you ordered.

 INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 WARNING 

If equipment is not used in a manner not specified by M-
System, the protection provided by the equipment may be 
impaired.

 CONFORMITY WITH EC DIRECTIVES

• This equipment is suitable for Pollution Degree 2 and  In

-

stallation Category II.  Reinforced insulation (signal input 

or output 1 or output 2 to power input: 300V) and basic 
insulation (signal input to output 1 to output 2: 300V) are 
maintained.  Prior to installation, check that the insula

-

tion class of this unit satisfies the system requirements.

• Altitude up to 2000 meters
• The equipment must be mounted inside a panel.
• The  equipment  must  be  installed  such  that  appropriate 

clearance and creepage distances are maintained to con-
form to CE requirements.  Failure to observe these re-
quirements may invalidate the CE conformance.

 POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

  100 – 240V AC rating: 85 – 264V, 
     

47 – 66 Hz, approx. 4 – 6VA

  24V DC rating: 24V ±10%, approx. 3W
  11 – 27V DC rating: 11 – 27V, approx. 3W

 

110V DC rating: 85 – 150V, approx. 3W

 GENERAL PRECAUTIONS

• Before you remove the unit from its base socket or mount 

it, turn off the power supply and input signal for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +55°C     

(23 to 131°F) with relative humidity within 30 to 90% RH 

in order to ensure adequate life span and operation.

• Be sure that the ventilation slits are not covered with ca

-

bles, etc.

 WIRING

• Do  not  install  cables  (power  supply,  input  and  output) 

close to noise sources (relay drive cable, high frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

• The unit is designed to function as soon as power is sup

-

plied, however, a warm up for 10 minutes is required for 

satisfying complete performance described in the data 
sheet.

• With  voltage  output,  do  not  leave  the  output  terminals 

shortcircuited for a long time.  The unit is designed to en-
dure it without breakdown, however, it may shorten ap-
propriate life duration.

COMPONENT IDENTIFICATION

Model

SPAN

ZERO

SPAN

ZERO

Fixing Screw

Zero Adj.

Span Adj.

Zero Adj.

Span Adj.

Connection

Diagram

Specifications

Output 1

Output 2

*

*

Provided only for dual output.

Body

Base Socket

INSTALLATION

Loosen the fixing screw at the front of the unit in order to 

separate the body from the base socket.

 DIN RAIL MOUNTING

Set the base socket so that 

its  DIN  rail  adaptor  is  at 
the  bottom.    Position  the 

upper hook at the rear side 

of base socket on the DIN 

rail and push in the lower.  

When removing the socket, 
push  down  the  DIN  rail 
adaptor  utilizing  a  minus 

screwdriver and pull.

 WALL MOUNTING

Refer to “EXTERNAL DIMENSIONS.”

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor