EM-7804-H  Rev.7  P. 1 / 19

INSTRUCTION MANUAL

PNP TRANSISTOR OUTPUT MODULE, 16 points

(L

ON

W

ORKS

)

MODEL

R7L-DC16B

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Transistor output module  ..................................................(1)
NeuronID label  ...................................................................(2)

 

MODEL NO.

Confirm Model No. marking on the product is exactly what 
you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.
LNS Plug-in Software (model: R7LPLG) is usable to set up 
Functional Blocks.  For detailed information, refer to the 
R7PLG Users Manual.  The R7LPLG is downloadable at M-
System’s web site: http://www.m-system.co.jp

POINTS OF CAUTION

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

    24V AC rating: 24V ±10%, 50/60 Hz, approx. 80mA
    24V DC rating: 24V ±10%, approx. 50mA

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and output signal for safety.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

 

RESTRICTIONS WHEN USING LonMaker3.0 or 3.1 

• Operating Environment 

   Please use LonMaker3.0 under the Environment of LNS3 

Service Pack 8 and use LonMaker3.1 under the Environ-
ment of LonMaker3.1 Service Pack 3 or later.

   Please use resource files of LonMark Resource File Ver12 

or later.

• LNS Plug-in Software is not usable. 
• The network variable of nvoCNTOut (fbCNT) is only 

SNVT_count_f.

• When registering a Device on LonMaker, please don’t use 

the following items.

  External Interface Definition / Upload From Device
  Specify Device Channel / Auto-Detect

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

Summary of Contents for R7L-DC16B

Page 1: ...ore you remove the unit or mount it turn off the power supply and output signal for safety ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ventilation Do not install the unit where it is subjected to continuous vibration Do not subject the unit to physical impact Environmental temperature must be within 10 to 5...

Page 2: ...s stopped OFF Normal state DISCRETE OUTPUT STATUS INDICATOR LED Used to show discrete output signal status ON LED ON OFF LED OFF SERVICE SWITCH Used to identify the node in LONWORKS network configura tion RESET SWITCH Used to reset the Neuron Chip Press the switch behind the front cover to reset Control functions are halted while completing resetting and restarting Confirm no danger before conduct...

Page 3: ...20 DIN RAIL 35mm wide 54 2 13 17 66 4 5 6 7 1 2 3 10 11 12 13 2 3 4 1 15 16 17 18 7 8 9 6 14 5 3 12 5 5 22 50 1 97 18 5 73 115 4 53 7 M3 SCREW TERMINALS for LONWORKS POWER 18 M3 SCREW TERMINALS for OUTPUT 6 24 6 24 CONNECTION DIAGRAM 4 7 6 3 2 5 1 V U FG NET2 NET2 NET1 NET1 Output Connection Example 10 17 18 1 YD 16 YB 0V YF 15 Y9 14 Y7 13 Y5 12 Y3 11 Y1 9 YE 8 YC 7 YA 6 Y8 5 Y6 4 Y4 3 Y2 24V Y0 2...

Page 4: ...CONNECTION HOST PC LONWORKS R7L LONWORKS R7L LONWORKS Terminator WIRING INSTRUCTIONS SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal size Spade tongue type is also applicable Applicable wire size 0 25 to 1 65 mm2 AWG 22 to 16 Recommended manufacturer Japan Solderless Terminal MFG Co Ltd Nichifu Co Ltd 6 24 max 3 3 13 max mm inch ...

Page 5: ...CPToemType SCPTserialNumber Extension module setting Maximum sending time per fb Minimum sending time per fb Set Tag No name Indicate Model No and Version Indicate Serial No NodeObject Network Variables Configuration Properties Network Variables NETWORK VARIABLE TYPE Range Default EXPLANATIONS nviRequest SNVT_obj_request For use with LonMaker and other tools nvoStatus SNVT_obj_status For use with ...

Page 6: ...0 0 0 Maximum time interval to send network variables per fb Power supply must be reset when this configuration prop erty is changed Network variables are sent out in the specified intervals even when there is no change in the value No sending when a value less than 10 0 is set Invalid property when the assigned fb has no network vari ables to be sent to the network SCPTminSendTime Number of fb SN...

Page 7: ...oCNTOut Set the maximum count Set the value when fbCNT is reset fbCNT SCPTdirection nviCNTIn SCPTinvrtOut nviCNTCtrl SCPTpwrUpState nvoCNTOut SCPTnvType SCPTmaxRnge SCPTsetpoint Network Variables Configuration Properties Network Variables NETWORK VARIABLE TYPE Range Default EXPLANATIONS nviCNTIn SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Counted object nviCNTCtrl SNVT_switch 0 0 0 100 0 1 Invalid 0 0...

Page 8: ...p 1 Count always reset to 0 Bit 5 8 through 15 Invalid Minimum input pulse width 500 ms for nviCNTIn 50 ms for the input terminals DO NOT connect a network variable to nviCNTIn when one of the input terminals other than nviCNTIn is assigned as the counted object ON time per 1 second increments SCPTinvrtOut nviCNTIn SNVT_lev_disc ST_OFF ST_ON ST_OFF Count logic at nviCNTIn ST_OFF Count with nvoCNTI...

Page 9: ... Y5 Y7 Y9 YB YD YF State Mode Output nviDO status Output nviDOOvr status Momentary Mode 1 or 2 One shot output at ON nviDO or nviDOOvr at ON One shot output at OFF nviDO or nviDOOvr at OFF nviDO SNVT_switch nviDOOvr SNVT_switch nv 68 nv 75 nv 60 nv 67 nv 76 nv 83 Output Terminal v s fbDO Network Variables nviDO nviDOOvr Assignments FUNCTIONAL BLOCK NETWORK VARIABLE OUTPUT TERMINAL fbDO 0 nviDO Y0 ...

Page 10: ...nviDOOvr is other than Invalid One shot output is provided at either Y0 or Y1 depending upon nviDOOvr value nviDOOvr SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 nvoDOStat SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Outputs last one shot output status Configuration Properties Common CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATIONS SCPTdirection SNVT_state 0 or 1 0 0 0 0 0 0 0 0 0 0 0...

Page 11: ...nviCMPIn2 SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Connects to the network variable to be compared nvoCMPOut SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 nviCMPIn1 and nviCMPIn2 are compared OFF is output when both val ues are equivalent ON or Invalid is output when they are not ON is output when nviCMPIn1 status change caused the discrepancy Invalid is output when nviCMPIn2 status change caused it OFF ...

Page 12: ...viENIn1 SNVT_switch nv 112 nv 115 nviENIn2 SNVT_switch nv 116 nv 119 nviENIn3 SNVT_switch nv 120 nv 123 nviENIn4 SNVT_switch Network Variables NETWORK VARIABLE TYPE Range Default EXPLANATIONS nviENIn1 SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Encoder input 1 nviENIn2 SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Encoder input 2 nviENIn3 SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Encoder input 3 nviENIn4 SNVT...

Page 13: ...In4 nvoENOut VALUE OFF OFF OFF OFF SCPTvalueDefinition 0 ON OFF OFF OFF SCPTvalueDefinition 1 OFF ON OFF OFF SCPTvalueDefinition 2 ON ON OFF OFF SCPTvalueDefinition 3 OFF OFF ON OFF SCPTvalueDefinition 4 ON OFF ON OFF SCPTvalueDefinition 5 OFF ON ON OFF SCPTvalueDefinition 6 ON ON ON OFF SCPTvalueDefinition 7 OFF OFF OFF ON SCPTvalueDefinition 8 ON OFF OFF ON SCPTvalueDefinition 9 ON ON OFF ON SCP...

Page 14: ...r function With Invalid nvoTMROut is reset to the default status and the internal counter is reset nvoTMROut SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Timer output Configuration Properties Common CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATIONS SCPTdirection SNVT_state 0 or 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit 0 fbTMR operating mode 0 One shot mode 1 Cyclic mode Bit 1 through...

Page 15: ...ains on Set Invalid at nviTMRIn to turn nvoTMROut off Example Providing one shot output when nviTMRIn is turned on SCPTtimeout 0 One shot output delay time SCPTtimeout 1 Pulse width SCPTtimeout 2 800 1 Holds nvoTMROut when nviTMRIn is turned off If SCPTtimeout 2 equals other than 800 1 the pulse width equals the addition of SCPTtimeout 1 and SCPTtimeout 2 Turning nvoTMROut on in a specific time pe...

Page 16: ...ariables Configuration Properties Extension discrete output Y0 Y2 Y4 Y6 Y8 YA YC YE Output nviDOEX1 status Y1 Y3 Y5 Y7 Y9 YB YD YF Output nviDOEX2 status nv 4 nv 11 nviDOEX1 SNVT_switch nv 12 nv 19 nviDOEX2 SNVT_switch Output Terminal v s fbDOEX Network Variables nviDOEX1 nviDOEX2 Assignments FUNCTIONAL BLOCK NETWORK VARIABLE OUTPUT TERMINAL fbDOEX 0 nviDOEX1 Y0 nviDOEX2 Y1 fbDOEX 1 nviDOEX1 Y2 nv...

Page 17: ... on or off Y1 Y3 Y5 Y7 Y9 YB YD YF of the extension module depending upon this input 100 0 1 ON Other OFF Configuration Properties CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATIONS SCPTdirection SNVT_state 0 or 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit 1 Output held or not at power off 0 OFF at the power startup 1 Outputs the held status at the power startup Bit 0 Bit 2 through 1...

Page 18: ... X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF Normal Mode Status output at nvoDIEX1 Status output at nvoDIEX2 Combination Mode Refer to the table in the next page fbDIEX SCPTdirection nvoDIEX1 SCPTinvrtOut nvoDIEX2 SCPTinvrtOut Set operating mode Invert output Invert output Input Terminal v s fbDIEX Network Variables nvoDIEX1 nvoDIEX2 Assignments FUNCTIONAL BLOCK NETWORK VARIABLE INPUT TERMINAL fbDIEX 0 nv...

Page 19: ...XC XE X1 X3 X5 X7 X9 XB XD XF nvoDIEX1 nvoDIEX2 OFF OFF 0 0 0 OFF Invalid ON OFF 100 0 1 ON Invalid OFF ON 0 0 0 OFF 0 0 0 OFF ON ON 100 0 1 ON 100 0 1 ON nvoDIEX2 SNVT_switch 0 0 0 100 0 1 Invalid 0 0 0 Configuration Properties CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATIONS SCPTdirection SNVT_state 0 or 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bit 0 Bit 1 fbDIEX operating mode 0...

Reviews: