R5CON USERS MANUAL  EM-9272 Rev.10

1. GENERAL

In this manual, user is assumed that he/she is already familiar with operating  Windows 7 or Windows 10 and terminology 
used in these operating systems.
If you need to know about particular operation or terminology on Windows, please refer to manuals provided with the system.

1.1  FEATURES OF R5CON

The R5 Series are isolated, modular I/Os with open field networking capabilities, such for DeviceNet and Profibus.  These 
network modules can be directly connected to a Windows PC via PC Configurator Cable.
The R5CON software is used to help you program various parameters such as I/O scaling, zero/span adjustments to match 
the users’ needs.
General functions of the R5CON are as follows:

 

PARAMETERS CONFIGURATION FOR EACH CHANNEL

I/O range scaling and zero/span adjustments are available for each I/O module.
For temperature input modules, actual temperature range can be also programmed per each command.
For T/C input of the model R5(T)-TS (Ver 1.00 or higher), overrange limits (0% and 100% of the scaled range) can be applied.  
When the input goes below 0% or above 100%, 0% and 100% data respectively are sent to the host PLC or PC.

 

FILE MANAGING

The parameter configuration for each module can be saved as a file on the PC.  Therefore, you can configure a set of param-
eters without actually connecting the R5x to your PC.
Reading (downloading) parameter files to the network module and each I/O module helps you to configure multiple modules 
easily and accurately.

 

MONITORING

You can check analog I/O data using configured data.
For discrete I/O modules, ON/OFF status of each channel can be monitored.

1.2  HARDWARE REQUIREMENTS

• 

DOS/V compatible PC with Windows 7 (32-bit, 64-bit) or Windows 10 (32-bit, 64-bit) appropriately installed.

• 

PC configurator cable, model MCN-CON or COP-US

1.3  INSTALLING THE R5CON

(1) Start up Windows.
(2) Go to M-System’s web site (http://www.m-system.co.jp).  Download and save the R5CON archive in your PC’s local hard 

disk.

(3) Confirm the size and version number of the downloaded archive (‘x’ in the file name as shown below). R5CON_Rx.exe or 

R5CON_Rx.zip

(4) Double-click the file’s icon and locate ‘R5CON_Rx’ folder.
(5) Start up setup.exe in the folder and follow instructions on the screen. Now the R5CON program has been installed.

CAUTION !

If you have already the R5CON program installed in your PC, remove it following the procedure explained in “1.4 
UNINSTALLING THE R5CON” before installing a new one
.

Summary of Contents for R5 Series

Page 1: ...ries Remote I O R5X PC CONFIGURATOR Model R5CON Users Manual http www m system co jp 5 2 55 Minamitsumori Nishinari ku Osaka 557 0063 JAPAN Tel 81 6 6659 8201 Fax 81 6 6659 8510 E mail info m system c...

Page 2: ...6 2 3 CONNECTING DISCONNECTING THE COMMUNICATION LINE 8 3 VIEWS FUNCTIONS PARTICULAR TO MODULES 9 3 1 ANALOG I O MODULE 9 3 2 THERMOCOUPLE RTD INPUT MODULE 10 3 3 CT PT AC CURRENT VOLTAGE INPUT MODUL...

Page 3: ...respectively are sent to the host PLC or PC FILE MANAGING The parameter configuration for each module can be saved as a file on the PC Therefore you can configure a set of param eters without actually...

Page 4: ...program or Program and feature Property dialog box of Programs and feature appears on the display 3 Choose R5CON among the list of installed applications 4 Choose Add Remove 5 Remove Programs From You...

Page 5: ...I O module 2 1 STARTING QUITTING THE R5CON Display images shown in this manual may change in detail when the software version is updated STARTING THE R5CON Press Start on the task bar and choose R5CON...

Page 6: ...cation line CONTROL PANEL Card No list Shows the selectable card numbers Click the arrow at the right to choose a card number in order to switch the main frame from Overview to the detail view for the...

Page 7: ...version Input Type Type of thermocouple and RTD Type I O Card Module Type None No card mounted Model No One of the Model No mounted Ch 1 Value Ch 2 Value Analog I O value for Ch 1 Analog I O value fo...

Page 8: ...up on the screen Confirm that the power is supplied to the R5 modules and that the configurator jack of the R5 network module and the COM port of the PC is firmly connected with the attached cable Ch...

Page 9: ...d No Shows Slot No Card Type Shows I O module hardware type Version No Shows firmware version No Zero Scale Enter 0 scaling value 32000 to 32000 Full Scale Enter 100 scaling value 32000 to 32000 Bias...

Page 10: ...Span Adj Enter fine 100 adjustment value gain 3 2000 to 3 2000 Zero Base Enter 0 temperature factory setting 0 As shown on the display Full Base Enter 100 temperature factory setting 0 As shown on th...

Page 11: ...No Shows Slot No Card Type Shows I O module hardware type Version No Shows firmware version No Zero Scale Enter 0 scaling value 32000 to 32000 Full Scale Enter 100 scaling value 32000 to 32000 Bias Ze...

Page 12: ...ws I O module hardware type Version No Shows I O module s firmware version No DI Data Shows current input data status 3 5 DISCRETE OUTPUT MODULE Item Function Card No Shows Slot No Card Type Shows I O...

Page 13: ...Download button Downloading the setting on the current display to the R5 module Item Function Selectable Range must be used within this range Card No Shows Slot No Card Type Shows I O module hardware...

Page 14: ...TCP port number is 502 502 Linger Enter time to close TCP Socket factory set to 1800 TCP Socket closed after no communication Set 1800 for 180 0 sec for the preset time This function is selectable wi...

Page 15: ...Save on the menu bar 3 Specify a location and a file name to save 5 2 READING PARAMETERS Click Open in the pulled down menu The PC Program reads the saved parameters but are not downloaded automatica...

Reviews: