INSTRUCTION MANUAL

Mini-M

ANALOG SWITCHING MODULE

MODEL

M2MNV

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Signal conditioner (body + base socket) ............................ (1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• This equipment is suitable for Pollution Degree 2 and In-

stallation Category II (transient voltage 2500V).  Rein-
forced insulation (signal channel or switching command 
contact to power: 300V) and basic insulation (signal chan-
nel to switching command contact: 300V) are maintained.  
Prior to installation, check that the insulation class of 
this unit satisfies the system requirements.

• Altitude up to 2000 meters.
• The equipment must be mounted inside a panel.
• The equipment must be installed such that appropriate 

clearance and creepage distances are maintained to con-
form to CE requirements.  Failure to observe these re-
quirements may invalidate the CE conformance.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

• Install lightning surge protectors for those wires connect-

ed to remote locations.

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

    100 – 240V and 85 – 264V AC rating: 
     

 85 – 264V, 47 – 66 Hz, approx. 3 – 5VA

    24V DC rating: 24V ±10%, approx. 2W
    11 – 27V DC rating: 11 – 27V, approx. 2W
    110V DC rating: 85 – 150V, approx. 2W

 

GENERAL PRECAUTIONS

• Before you remove the unit from its base socket or mount 

it, turn off the power supply and input signal for safety.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +55°C     

(23 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

• Be sure that the ventilation slits are not covered with ca-

bles, etc.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

COMPONENT IDENTIFICATION

Body

Base Socket

Fixing Screw

Connection

Diagram

Specifications

Model

 

FRONT PANEL CONFIGURATION

• Channel 2

  Status LED 2

• Channel 1

  Status LED 1

Power LED

Summary of Contents for Mini-M M2MNV

Page 1: ...vel of this unit when it is integrated in a panel system The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conform ity Install lightning surge protectors for those wires connect ed to remote locations POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operati...

Page 2: ...ng a minus screwdriver and pull WALL MOUNTING Refer to EXTERNAL DIMENSIONS TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit EXTERNAL DIMENSIONS unit mm inch 4 8 7 10 11 5 6 1 2 3 9 22 87 6 24 59 2 32 11 M3 SCREW 72 2 83 29 5 1 16 2 4 2x5 17x 20 MTG HOLE 6 24 deep When mounting no extra space is needed between units 21 5 85 70 ...

Page 3: ...G 22 to 16 Recommended manufacturer Japan Solderless Terminal MFG Co Ltd Nichifu Co ltd 6 24 max 3 3 13 max mm inch CHECKING 1 Terminal wiring Check that all cables are correctly con nected according to the connection diagram 2 Power input voltage Check voltage across the terminal 10 11 with a multimeter 3 Switching command contact Confirm adequate opera tions of the contact signal LIGHTNING SURGE...

Page 4: ...r ON Switching command OFF to ON or Power ON Switching command ON to OFF Current Signal receiving resistor 50 Ω Voltage Signal 1 Resistor is provided only for the input code 2 Current signal receiving resistor 50 Ω 1 Resistor is provided only for the input code 2 Current signal receiving resistor 50 Ω 1 1 1 1 1 2 4 5 7 8 1 2 4 5 7 8 1 1 1 1 Switching Status When the switching command contact is sw...

Reviews: