INSTRUCTION MANUAL

MULTI POWER TRANSMITTER

(self-powered, PC programmable)

MODEL

M5XWTU

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Signal conditioner ...............................................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.
The M5XWTU is programmable using the PC Configurator 
Software.  For detailed information on the PC configuration, 
refer to the PMCFG users manual.  The PMCFG PC Con-
figurator Software is downloadable at M-System’s web site: 
https://www.m-system.co.jp
Refer to EM-2768-B for the use of Modbus.

POINTS OF CAUTION

 

AUXILIARY POWER

• M5XWTU does not have input terminals for auxiliary 

power.  The power for operation is generated from the 
voltage input terminals P1 - P2, with consuming 3 VA be-
tween these terminals.

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the input 

signal for safety.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -20 to +65°C 

(-4 to +149°F) with relative humidity within 30 to 90% 
RH in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

• Install lightning surge protectors for those wires connect-

ed to remote locations.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

COMPONENT IDENTIFICATION

Terminal Cover

Power Indicator LED

Configurator Jack

Body

Specification

Terminator DIP SW

for Modbus

INSTALLATION

Set the unit so that its DIN rail adapter is at the bottom.

 

MOUNTING THE UNIT ON A DIN RAIL

A) Hang the upper hook at the rear side of unit on the DIN 

rail.

B) Push in the lower in keeping pressing the unit to the DIN 

rail.

A

B

DIN rail

 

REMOVING THE UNIT

A) Pull down the DIN rail adaptor using a minus screwdriv-

er.

B) Pull out the lower part of the unit.
C) Remove the upper part from the DIN rail.

A

Slider

C

B

Summary of Contents for M5XWTU

Page 1: ...e unit or mount it turn off the input signal for safety ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ventilation Do not install the unit where it is subjected to continuous vibration Do not subject the unit to physical impact Environmental temperature must be within 20 to 65 C 4 to 149 F with relative humidi...

Page 2: ...RAM 1 8 2 4 7 1K Current sensor to other Modbus devices Voltage input COM P2 P1 P3 3K 3 5 6 DA DB JACK CONFIGURATOR TERMINAL CONNECTIONS P1 P2 P3 1K 3K sourse load u v v u U V V U k l K L k l K L P1 P2 P3 1K 3K R sourse load N T R S T R N T R S T k l K L k l K L P1 P2 1K R sourse load N k l K L u v U V P1 P2 1K COM COM COM COM R sourse load N k l K L System Application Single phase 2 wire Note Use...

Page 3: ...rque 0 8 N m EXTERNAL VIEWS LEFT VIEW FRONT VIEW Terminator DIP SW for Modbus Term On Power Indicator LED Configurator Jack PC CONFIGURATOR Use PC Configurator Software model PMCFG to set all the parameters such as wiring type and sensor type Refer to the users manual for the PMCFG for detailed operation of the software program CHECKING 1 Terminal wiring Check that all cables are correctly con nec...

Page 4: ...inks in different patterns indicating various oper ating status The following figure indicates typical patterns LED ON OFF PATTERNS TRANSMITTER STATUS Downloading the setting Loop test Normal Abnormal Operation corruption of configuration data 80ms LIGHTNING SURGE PROTECTION M System offers a series of lightning surge protector for protection against induced lightning surges Please contact M System...

Reviews: