20
JC-IO USERS MANUAL EM-9044-B
4.4.2 Communication (HTTP/SNTP)
After reading the configurations, following screen will appear.
Following items are configurable in the [Communication.] tab.
Figure 8. Communication Setting Screen
Table 20. Communication setting
ITEM
DESCRIPTION
HTTP
Set whether or not to use the Web server function, and set
the login information when using.
32 characters or less, and alphanumeric characters and
underscore are allowed for login information (login and
password).
SNTP
Set whether or not to use the automatic time correction
function, and set the necessary information when using.
Enter the domain name of the SNTP server in 32 charac-
ters or less with ASCII characters to the "Server" field.
In the Time Zone field, set to +09:00 in case of using in
Japan.
Setting the start time of the time correction.
When connecting multiple JC-IO-N units to one router, set
this time a few minutes apart.
COM
Change the COM port number.
save file
Save the current configurations to the file.
Upload to device
Upload the current configuration to the device.
Quit
Quit the configuration and back to the initial starting screen.
Consult with your network administrator to configurate the settings.
Reboot the unit to apply the settings.