background image

20VS5-2

P. 1 / 2

EM-4427 Rev.1

CLOCK GENERATOR

MODEL

20VS5-2

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Clock generator ............................................................. (1)

 MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 POWER INPUT RATING & OPERATIONAL RANGE

• Power Supply

  Operational voltage range: 15 V DC ±5 %

  Power consumption: Approx. 7 mA DC (no load), approx. 

15 mA per one 20VS5-210 or 20VS5-213.

  Install the filter for the power supply as indicated below.

10µF

+

COM

POWER

560µH

1

8

+15V

10µF

+

 ENVIRONMENT

• Indoor use
• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +70°C 

(14 to 158°F) with relative humidity within 30 to 90% RH 

in order to ensure adequate life span and operation.

 WIRING

• Do  not  install  cables  (power  supply,  input  and  output) 

close to noise sources (relay drive cable, high frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 INSTALLING THE MODULE

When it is installed on the printed wiring board, land diam-

eter ø1.5 and through-hole ø0.9 are recommended.

 AND ....

• The unit is designed to function as soon as power is sup

-

plied, however, a warm up for 10 minutes is required for 

satisfying complete performance described in the data 
sheet.

• Do not leave the output terminals shortcircuited for a long 

time.  The unit is designed to endure it without break-
down, however, it may shorten appropriate life duration.

CHECKING

1)  Terminal wiring: Check that wiring is correctly connect-

ed according to the connection diagram.

2)  Power input voltage: Check voltage across the pins.

TERMINAL CONNECTIONS

 EXTERNAL DIMENSIONS mm (inch) 

MAX. 27 (1.06)

1 2

6

9

4 (.16)

1

(.04)

MAX16.5

(.65)

7.5

(.3)

7.62

(.3)

0.5

(.02)

2.54

(.1)

12.7 (.5)

10.16 (.4)

PIN ASSIGNMENT

1

POWER SUPPLY (+)

2

CLOCK OUTPUT

6

SYNC IN

7

SYNC OUT

8

POWER SUPPLY (-)

9

CLOCK COMMON

Reviews: