79
IDM 510-066-1
K12 sealing unit
English language
Operation and maintenance manual
Flap length adjustment
This action is necessary to adjust the length of the adhesive tape flap.
The lower and upper flap can be set with different lengths according to the produc-
tion requirements.
–
The intervention must be carried out with the machine stopped in safety condi-
tions.
Attention
Warning
Wear the suitable personal protective equipment (gloves) to avoid any cutting haz-
ard.
▀
Upper sealing unit (flap 70 mm)
1.
Remove the adhesive tape from the
sealing unit.
2.
Components
A-B-C
must be in-
stalled as shown in the figure.
3.
Apply tape stretcher to the adhesive
side of the tape.
4.
Guide tape stretcher until the tape
stretcher is beyond the point of tan-
gency of case inlet roller.
5.
Cut the adhesive tape close to tape
stretcher.
The part of exceeding adhesive tape
must not be lower than the flap
length.
–
Remove components 50 mm in or-
der to obtain a 50 mm flap.
–
To obtain a 30 mm flap, request
component E and replace to the
one installed.
▀
Lower sealing unit (flap 70
mm)
1.
Lift upper conveyor completely.
This operation is necessary to assist the operations.
2.
Remove lower sealing unit
– Repeat the operation according to the procedure described for upper sealing unit.
3.
Insert sealing unit into its original housing.