FES Maintenance manual, v1.16 May 2020
Page 22 of 24
9. Repairs
9.1 List of potential problems
The charger does not start charging
Check if the power cord is plugged into a wall
outlet
The charger does not start charging
Check if the connecting cable is connected
between the battery pack (DATA) and charger
The charger does not start charging
Check electrical grid fuse
The capacity indicator is not showing
full batteries in the FCU after the
installation of fully charged batteries.
You must wait about 8 seconds after the power
switch is turned ON. Additionally, the total
voltage level of packs must be above 114V.
FCU is not showing remaining time
Enter code 00040 and then 00030
Voltage and current measurement are
not available
Check connectors on LXUI box
The motor does not start, or it starts
briefly and then stops unexpectedly
Check power switch, flip it OFF an ON a few
times
Please use the following template when you are reporting a problem with the FES system:
FCU serial number
FCU software version
With power switch OFF *
Are battery pack temperatures available?
Is the motor temperature available?
With power switch ON, and the motor
stopped*
Does the "OK" LED on the FCU light up?
Does the FCU display the
»CONTRO
L
LER READY«
message?
Is the FCU "ERROR" LED glowing or blinking?
Is the controller temperature available?
Is voltage measurement data available?
What is the voltage level?
Does FCU display any messages? Which ones?
With power switch ON and motor running *
Does the "OK" LED on the FCU light up?
Does the FCU display the »CONTROLLER READY«
message?
Is the FCU "ERROR" LED glowing or blinking?
Is the current measurement data available?
Is the power consumption calculation available?
Is RPM displayed?
Does FCU display any messages? Which ones?
*If possible, take a photo of the FCU main screen and info page.