46
DSX
CLIO:
Perform MLS or Sinusoidal measure, preferably using 51,200 of sampling rate and a 1/6 octave smoothing
for MLS and a resolution of at least 1/24 octave in the Sinusodial case. Once done, export as ASCII
format pressing Shift + F2, which will generate a file with the name you want and extension *.txt that can
be read by our software.
The text file accepted will look like this:
Freq
dB
Phase
20.0
84.7
87.81
20.3
84.5
89.54
20.5
84.4
91.46
20.8
84.3
93.55
21.1
84.3
95.84
21.3
84.3
98.33
21.6
84.4
101.02
..
..
..
LINEAR X - LMS:
In Linear X - LMS to get the ASCII file you have to measure, export the transfer function in magnitude and
phase and give the name to the file which will be a *.txt format, and this must be equal to that shown
below to be accepted by the software.
* LMS(TM) 4.5.0.352 Jul/01/2007
* (C)copyright 1993-2000 by LinearX Systems Inc
* Oct 4, 2007 Tue 11:15 am
* Library=Remeasure Production Cabinet COmponents.lib
* Curve=Blackbird Prodn Cab HIGHS 4w4m, GP, HF_Vert 90' WI
* Info1=
* Info2=
* Info3=
* Info4=Data Measured: Jan 31, 2007 Mon 4:24 pm
* DataPoints= 552
* DataUnits= Hz dBSPL Deg
+1.001, -2.001, -4.000
+1.001, -2.001, -4.000
+1.001, -2.001, -4.000
+1.001, -2.001, -4.000
+1.001, -2.001, -4.000
..
..
..