LYALL LYCO LHP-200 Installation Procedure Download Page 1

CUSTOMER SERVICE: 1 (800) 535-9255

Page 1

Doc#

 

LIT-LCLHPRPINST

Rev.

 

2

©

 

201

R.W.

 

Lyall

 

&

 

Company,

 

Inc.

LHP-200

LYCO

®

Hydraulic Press

Installation Procedure For LYCOFIT

®

Repair Fittings

1. Lubricate

LHP-200

shafts with

non

synthetic lubricant (e.g. 3in1 oil)

ONLY

.

2.

DO NOT

apply lubricants to the fittings, spigots or sleeves.

3. When installing a fitting to repair a pressurized pipe, insure that the area of repair is isolated

from the pressure supply before cutting the PE pipe.

4.

The

LHP-200

is intended for installing

LYCOFIT

®

fittings only.

5.

LYCOFIT

®

fittings are designed to be installed only on O.D. controlled Polyethylene (PE) pipe

made per ASTM D2513 & ASTM F2619. Examine the pipe print line and fitting labels and install
fittings only to pipe with the correct size designation and wall thickness/DR.

6. If the installation is for use in Natural Gas pipe lines, pressure test each assembled joint in com-

pliance with minimum requirements as specified in

D.O.T. CFR Title 49 Part 192, Sub Part J.

7. The

LHP-200

requires a hydraulic source to operate. The AHP100 (ENERPAC

P142) is

available through Lyall as a hand pump source for operating the

LHP-200

. Other hydraulic pow-

er sources (e.g. ENERPAC PA-133) with an output greater than 5500 psig may be used. The
pump source should be limited to an output of 6500 psig to restrict the stress applied to the tool
during installation of the fitting. (ENERPAC pump adjustment instructions are available by re-
quest from your customer service representative.)

Repair Clearance Requirements:

Important:

19”

19”