Installation
PowerMouse can be installed behind the instrument panel.
5.1
Connecting LXNAV PowerMouse
LXNAV PowerMouse is connected to DC power supply using PF POWER 12 VDC cable. Red wire goes
to + positive and blue wire goes to
–
ground.
External indicator can be connected via a splitter or directly to the other port.
Instrument has no internal fuse.
3A external fuse is required!
5.2
Connecting Antennas
PowerMouse has 4 connectors for different antennas. Two SMA connectors (A and B) are for Flarm
Antennas and there is one antenna for the ADSB (optionally). GPS connector serves for GPS antenna
and BT connector for Bluetooth antenna.
Following Flarm Antennas are available:
•
Short Dipole (90°) lambda/4
•
Long dipole (90°) lambda/2
•
Flat folded dipole
•
Classic dipole
•
Antenna with ground plate
For better range, Flarm antennas must be positioned vertically.
For additional information about installation you may have a look at:
https://flarm.com/wp-content/uploads/man/FTD-041-Application-Note-FLARM-
Antenna-Installation.pdf
1x Flarm Flat dipole antenna is included in the package.