LW MEASUREMENTS Army Aviation SCT Series Manual Download Page 1

1

 

 
 
 
 
 
 

Army Aviation 

SCT Series 

Electronic Counting 

Scale Manual 

 
 
 
 

 

 

 

Summary of Contents for Army Aviation SCT Series

Page 1: ...1 Army Aviation SCT Series Electronic Counting Scale Manual...

Page 2: ...N 4 2 1 BODY INSTALLATION 2 2 BATTERY REPLACEMENT 3 INSTRUCTION 5 3 1 PARAMETERS 3 2 POWER SUPPLY 4 DISPLAY 6 4 1 PANEL DESCRIPTION 4 2 KEY DESCRIPTION 4 3 DISPLAY DESCRIPTION 5 OPERATION 9 6 FUNCTION...

Page 3: ...nd maintenance in this manual In order to apply the scale well you must read the manual carefully before using 1 ATTENTION 1 1 CONVENTIONAL ATTENTION z The object is forbidden to fall down on the pan...

Page 4: ...ocation is changed 2 Connect the AC adapter to the independent power supply for avoiding interference from other equipments 3 Be sure no loads on the pan when turn scale on 4 Electrify to preheat the...

Page 5: ...nterface 2 2 BATTERY REPLACEMENT 1 Take down the pan open the housing and disconnect the battery joints 2 Put new battery in the position and connect poles correctly Warning The positive and negative...

Page 6: ...Rate 20 times Sec Resolution 1 million 3 2 POWER SUPPLY AC Adapter Input 100V 240V Output 12V 1A Battery Specification 6V4AH 4 DISPLAY 4 1 PANEL DESCRIPTION R2 R1 SCT Panel Description HI red light O...

Page 7: ...PRINT Perform Print Function UWS Confirm the input unit weight CK Cooperate with other keys to set the upper lower limit RETURN Return to weighing interface when setting M HI 1 Perform accumulation fu...

Page 8: ...4 3 DISPLAY DESCRIPTION No Description No Description 1 Stable Symbol 7 MR Symbol 2 Zero Symbol 8 MC Symbol 3 Symbol 9 R1 cap Symbol 4 NET Symbol 10 R2 cap Symbol 5 Battery Symbol 11 Samples Lack 6 M...

Page 9: ...ows in SCT series scale in which weight unit weight and count are displayed respectively 5 3 AVERAGE UNIT WEIGHT SETTING If average unit weight was not set 0 will be displayed in unit weight and count...

Page 10: ...e the container 4 Input the number of samples by numeric keyboard and the number is displayed on unit weight screen 5 Press SMPL key to display the unit weight value on unit weight screen and sampling...

Page 11: ...ng and count according to the item 5 3 2 Press M HI key to display current accumulated times for short time on unit weight screen and one second later automatically return in counting interface 3 The...

Page 12: ...examine each message of 10 times accumulated results in ascending order 5 Press RETURN key to return in counting interface 5 6 CLEAR ACCUMULATION FUNCTION Clear Accumulation Function can be used to c...

Page 13: ...accumulated results 5 Press RETURN key to return in counting interface 5 7 CHECK WEIGHT Check Weight mode and check weight alarm range function can be set under function setting mode The setting inst...

Page 14: ...d press SMPL key to confirm the upper limit weight 4 Press RETURN key to return in counting interface 5 Press CK key and press RSMPL key again to open check weight function 6 Press CK key and press RE...

Page 15: ...t count by numeric keyboard press SMPL key to confirm the lower limit count 3 Press M HI key to display check count alarm range on weight screen upper limit count on unit weight screen HI on count scr...

Page 16: ...on unit weight screen 2 Input 1139 by pressing numeric keys and press SMPL key to display CAL on weight screen 1Point on unit weight screen C ZEro on count screen 3 Confirm no load on the pan and pre...

Page 17: ...les to be legal measure unit 1 In the condition of power off hold on SMPL key and press ON OFF key to enter in function setting display set on weight screen and 0 on unit weight screen 2 Input 1132 by...

Page 18: ...t 1136 by numeric keys and press SMPL key to display Auto Z on weight screen 1136 on unit weight screen Minimum Zero Display on count screen 3 Press 1 key to change the different minimum zero display...

Page 19: ...the pan press TARE key to set zero point calibration display 1 3 maximum capacity on count screen 3 Put the required weights on the pan for 3 5 seconds press TARE key to enter in next portion linear...

Page 20: ...n LiGh on unit weight screen backlight type on count screen Press 0 key to change backlight type OFF No Backlight ON Backlight is bright Auto Automatic Backlight No load no backlight as load greater t...

Page 21: ...FunC3 on weight screen CK bz on unit weight screen ON or OFF on count screen Press 3 key to change them 6 4 CHECK WEIGHT ALARM RANGE SETTING Press 4 key to display FunC4 on weight screen Limit on uni...

Page 22: ...on weight screen Prt on unit weight screen Print Pattern on count screen Press 6 key to change them PrtPr press PRINT key to print PrtCo continuous output to print PrtST stable output to print PrtMr a...

Page 23: ...ay FunCA on weight screen SMPL on unit weight screen E d on count screen Press key to change them E count according to external weight d count according to value of internal code 6 10 RS232 OUTPUT ACC...

Page 24: ...display Pr Wt on weight screen Pr UWt on unit weight screen Pr PCS on count screen at the moment weight unit weight and count can be printed and output 1 Press M HI key to change the display nP Wt on...

Page 25: ...gs PIN2 TXD PIN3 RXD PIN5 GND Setting Pattern Data bits 8 without odd even check stop bit 1 baud rate is adjustable 7 2 RS232 FORMAT Three print formats Continuous pressing key and stable G W 92 6 g G...

Page 26: ...al G W 278 1 g Weight of accumulated total U W 0 92658 g QTY 300 PCS Count of accumulated total 8 ERROR MESSAGES Symptom Possible Reason Solution Unable to boot No power or dead battery Check power an...

Page 27: ...pan Load cell damaged or PCB problem Working condition Eliminate objects Repair in factory System halted Can t power off key no response can t weigh etc Power and battery cut reconnect them to turn o...

Page 28: ...place any component s that proves to be defective at no charge exclude the artificial damage in the meantime you must show the invoice and valid warranty card of product to our service center In the f...

Page 29: ...29 Version VER 1 0 Subject to change without prior notice...