7. Hang the unit on the wall to complete the 

installation. Make sure the unit is seated prop-

erly. Apply silicon sealant on left and right 

sides of the shower panel. (

NOTE:

 do not seal 

the bottom of the panel, this will allow any 

possible future leaks to drain out the panel)

8. Attache shower head. Apply some (

NOTE:

 

PTFE tape on the thread to prevent leaking)

Installation (cont.)

7. Connect hand shower hose to the main 

panel body. Attach the hand shower to the 

hose. (

NOTE:

 Install the rubber washer to pre-

vent leak.)

Summary of Contents for SP26-GS-AQU

Page 1: ... Features Stunning stylish European inspired design Elegant safety tempered glass panel Available in white black silver and aqua blue colors Square stainless thin profile shower head 8 swivel massage jets 3 stage shower functions Rainfall Massage Spray Hand Shower Contemporary brass hand shower Tempered glass shelf ...

Page 2: ...igence improper installation product abuse product misuse or use of cleaners containing abrasives alcohol or other organic solvents whether performed by a contractor service company or yourself are excluded from this warranty Our responsibility under this limited warranty is limited to only to replacement parts and no other costs Luxier USA will not be responsible for labor charges and or damage i...

Page 3: ...e shower panel Keep the product in its package until you are ready to install Read and understand this installation guide completely Make sure the installation site is clean and free of dust and debris Please make sure the water supply is shut off to the installation area If necessary shut off the water to the entire house Turn on the water at a bathroom faucet in the house to relieve the pressure...

Page 4: ...ual product may vary depends on model Fig A This is the distance from the bottom edge of the shower panel to the shower panel inlet valve NOTE This distance vary by models always take the actual measurement from the shower panel A B The installation height of the outlet box is approximately the total distance of measurement A and measurement B It is recommened to aim the top hori zontal body jets ...

Page 5: ...Luxier SP26 GS Rev A3 122017 5 Technical Data Recommended Operating Pressure 50 80 PSI 340mm 13 39 240mm 9 45 1300mm 51 18 710mm 27 95 270mm 10 63 430mm 16 93 70mm 2 76 All Measurements are Approximate ...

Page 6: ...er Panel Body 06 Glass Shelf 07 Rubber Washwer 08 Locking Nut 09 Rubber Washer 10 Rainfall Shower Supply Connector 11 Hand Shower 12 Hand Shower Cradle 13 Rubber Washer 14 Hand Shower Hose 15 Screw x 4 16 Mounting Bracket x2 17 Wall Anchors x 4 Parts List 1 2 3 4 5 6 7 14 13 12 11 8 9 10 15 16 17 ...

Page 7: ...ng to complete the connection NOTE Make sure the silicon gasket 4 is seated properly inside the connector 1 2 3 4 5 1 Attach shower arm assembly to the panel body Make sure to install screen washer to protect shower head from debris in the plumb ing system 3 Mark the positions of the 2 brackets on the wall and set a side the panel NOTE The distance between the two brackets should be 710mm or 27 95...

Page 8: ... wall NOTE Before installing the wall anchors use a small piece of painters tape or masking tape over the drill area This will prevent damages to the tile 1 5 Secure the mounting brackets to the wall 6 Apply thread sealant tape to the threading on the shut off valves before connect both hot and cold water supply hoses to the valves Turn on the valves and check all connections for possible leaks ...

Page 9: ...ht sides of the shower panel NOTE do not seal the bottom of the panel this will allow any possible future leaks to drain out the panel 8 Attache shower head Apply some NOTE PTFE tape on the thread to prevent leaking Installation cont 7 Connect hand shower hose to the main panel body Attach the hand shower to the hose NOTE Install the rubber washer to pre vent leak ...

Page 10: ...et screws under the an chors to insert the glass shelf Tighten the set screws to secure the glass shelf WARNING Do not place heavy objects on the glass shelf Do not excess weight limit of 2 pounds when placing objects on the shelf Installation cont ...

Page 11: ... dishwashing soap and warm water for cleaning 3 Do not use abrasive harsh chemical when cleaning the fixture as they will damage and dull the finish 4 Carefully read the cleaner product label to ensure the cleaner is safe for use on the material 5 Test the cleaner on a small area before using on the entire surface 6 Do not leave the cleaner on the fixture longer than necessary 7 When using spray c...