75
GB
In case of a leak, turn off the gas supply.
Tighten any leaking fi ttings, then turn the
gas supply on and recheck.
Never leak test while smoking.
Operation and storage
To turn on the heater
1. Turn on the valve on the gas supply
cylinder completely.
2. Press and turn the variable control knob
to PILOT position (counter-clockwise 90°).
3. Press down the variable control knob
and hold for 60 seconds. While holding
down the variable control knob, press
the ignitor button several times until the
pilot fl ame lights. Release the variable
control knob after the pilot fl ame lights.
OFF:
the heater stop work
HI:
Maximum temperature position
LO:
Minimum temperature position
Note:
If a new cylinder has just been connected,
please allow at least one minute for the air
in the gas pipeline to purge out through the
pilot hole.
When lighting the pilot fl ame, make sure
that the variable control knob is continously
pressed down while pressing the igniter
button. The variable control knob can be
released after the pilot fl ame lights.
Pilot fl ame can be watched and checked
from the small round window with sliding lid
located at the bottom of the fl ame screen (to
the left or right side of the controller).
If the pilot fl ame does not light or it goes out,
repeat step 3.
4. After the pilot fl ame lights, turn the
variable control knob to maximum
position and leave it there for 5 minutes
or more before turning the variable
control knob to the desired temperature
position.
To turn off the heater
1. Turn the variable control knob to PILOT
position.
2. Press and turn the variable control knob
to OFF position.
3. Turn off the valve on the gas supply
cylinder completely.
variable control knob
Summary of Contents for 547705
Page 139: ...139 A B C D E F G H I...