background image

1

© COPYRIGHT 2005 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED

I M P O R T A N T !

Please read all instructions carefully before beginning

installation. Save them for future reference. Before removing

any wiring from your existing thermostat, its wires must be

labeled with their terminal designations. Ignore the color of the

wires since they may not comply with any standard.

PSP711CC SERIES

SMART TEMP ELECTRONIC THERMOSTAT

HEAT

OFF

COOL

SET

SUNDAY

WEEKDAY
PROGRAM

SET

DAY/TIME

PM

Choose Heat or Cool

Set Day and Time

Installs Easily

Easy as

1–2–3

Complete, Easy To Read

INSTALLATION AND OPERATING

INSTRUCTIONS

COMPATIBILITY

FEATURES

WARNING:

Use Energizer

®

or DURACELL

®

Alkaline Batteries Only.

Energizer

®

is a registered trademark of Eveready Battery Company, Inc.

DURACELL

®

is a registered trademark of The Gillette Company, Inc.

Thank you for your confidence in our product. To obtain the best

results from your investment, please read these instructions and acquaint
yourself with your purchase before installing your new thermostat. Then
follow the installation procedures, one step at a time. This will save you
time and minimize the chance of damaging the thermostat and the
systems it controls. These instructions may contain information beyond
that required for your particular installation. Please save for future
reference.

The PSP711CC can be used with most single stage 24 volt gas, oil or

electric heating and air conditioning systems, single stage heat pumps, or
gas millivolt heating systems. It cannot be used with 3 wire zone valves,
120 volt heating systems, or multi stage heat pumps. Ask your dealer for
other LUX thermostats to control those systems.

Small elegant design

Exclusive LUX Speed Dial

®

EL Illuminated Display

Comprehensive Graphical
Filter Monitor

7 Day Programming

Energy Star Compliant

4 Periods Per Day

Independent Fan Program

Programmable (minimum)
Fan Duty Cycle

Nonvolatile Memory For
All Programs And Settings

Temporary Temperature
Override

Temperature Hold

Keyboard Lockout

F/C Temperature Display

12/24 Hr Clock Display

Adjustable Temperature
Differential / Cycle Rate

User Temperature Offset /
Calibration

5/2 minute selectable
minimum Run/Off time provides
short cycle and compressor
protection

C A U T I O N

The PSP711CC is protected against normal static electric discharges.

To minimize the risk of damaging the unit in extremely dry weather,

touch a grounded metal object before touching your thermostat.

LUX PRODUCTS CORPORATION

Mt. Laurel, New Jersey 08054, USA      

43376

EASY

PROGRAMMING

WITH

LUX SPEED DIAL

®

UP

LARGE

BACKLIT
DISPLAY

DOWN

LIGHT

MODE SWITCH

IAQ 
INDEPENDENTLY
PROGRAMMABLE
FAN

INSTALLATION

Please read all instructions carefully before beginning installation.

TOOLS REQUIRED

#1 Phillips screwdriver (small)

Drill with 3/16-in. (4.8mm) bit

Wire stripper/cutter

THERMOSTAT LOCATION

On replacement installations, mount the new thermostat in place of the

old one unless the conditions listed below suggest otherwise. On new
installations, follow the guidelines listed below.
1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the
floor, and in a room that is used often.
2. Do not install it where there are unusual heating conditions, such as:
in direct sunlight; near a lamp, television, radiator, register, or fireplace;
near hot water pipes in a wall; near a stove on the other side of a wall.
3. Do not locate in unusual cooling conditions, such as: on a wall
separating an unheated room; or in a draft from a stairwell, door, or
window.
4. Do not locate in a damp area. This can lead to corrosion that may
shorten thermostat life.
5. Do not locate where air circulation is poor, such as: in a corner or an
alcove; or behind an open door.
6. Do not install the unit until all construction work and painting has
been completed.

REMOVING THE OLD THERMOSTAT

1. Switch electricity to the furnace and air conditioner
OFF; then proceed with the following steps.
2. Remove cover from old thermostat. Most are snap-
on types and simply pull off. Some have locking
screws on the side. These must be loosened.
3. Note the letters printed near the terminals. Attach
labels (enclosed) to each wire for identification.

Remove and label wires one at a time. Make sure the wires do not fall
back inside the wall.
4. Loosen all screws on the old thermostat and remove it from the wall.

MOUNTING THE PSP711CC

1. Strip insulation leaving 3/8 in.
(9.5mm) bare wire ends and clean off
any corrosion.
2. Fill wall opening with non-
combustible insulation to prevent drafts
from affecting the thermostat.

Y

W

Y

W

R

C A U T I O N

Read instructions carefully before removing any wiring from existing

thermostat.

Wires must be labeled before they are removed.

Do not allow wires to touch each other or parts on thermostat.

When removing wires from their terminals, ignore the color of the

wires since they may not comply with any standard.

Y

W

C A U T I O N

Be careful not to drop the unit or disturb electronic parts.

Leave the door closed while the body is being removed

from the base.

C A U T I O N

Turn off electricity to the appliance before installing or

servicing thermostat or any part of the system. Do not
turn electricity back on until work is completed. 

Do not short (jumper) across electric terminals on furnace or air

conditioner to test the system. This may damage the thermostat and
void your warranty.

All wiring must conform to local codes and ordinances.

The thermostat should be limited to a maximum of 1.5 amps;

higher current may cause damage to the thermostat.

Your thermostat is a precision instrument. Please handle it with

care.

OFF

3. Remove the body from the thermostat’s base by pressing the thumb
latch at the bottom center of the unit and swinging the body away.

N O T E

If you are mounting the base to soft material like plasterboard or if you

are using the old mounting holes, the screws may not hold. Drill a 3/16

in. (4.8mm) hole at each screw, and insert the plastic anchors provided.

Summary of Contents for LUXPRO PSP711CC series

Page 1: ...ons mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise On new installations follow the guidelines listed below 1 Locate the thermostat on an inside wall about 5 ft 1 5m above the floor and in a room that is used often 2 Do not install it where there are unusual heating conditions such as in direct sunlight near a lamp television radiator register ...

Page 2: ...bs on the base then snap the bottom of the unit into place Do not use unnecessary force If the body does not snap into place easily remove the body re hang it from the tabs and try again 10 Turn the power back on to your heating and or air conditioning system 11 Verify that the system and its fan are operating properly When set to a high temperature the heating system should provide warm air after...

Page 3: ...ps 3 10 described in WEEKDAY PROGRAMMING to program Saturday and Sunday START AT PROGRAM MORN SU AM HEAT SET 6 0070 CLEAN AIR CYCLE The CLEAN AIR CYCLE insures that the fan runs for at least the specified duration each hour to circulate and filter the air in your home Hourly fan run time may be specified from 9 to 60 minutes per hour 60 ON or continuous run The default minimum run time is 15 minut...

Page 4: ...nace and air conditioner OFF 2 To access your units batteries remove the unit from the wall by pressing up on the thumb latch at the bottom of thermostat and swinging the body up and away 3 Remove the used batteries 4 Install two new Energizer or DURACELL AA size alkaline batteries in the battery compartment Observe the polarity marking shown in the compartment 5 Hang the top of the unit by the ta...

Reviews: