StarLine
Led-profile
Order code: 10715
Page 1: ...StarLine Led profile Order code 10715...
Page 2: ...BURNS 6 3 4 PROTECTION FROM INJURY 7 3 5 DISPOSING OF THIS PRODUCT 7 4 PHYSICAL INSTALLATION 8 4 1 UNPACKING 8 4 2 MOUNTING 8 4 3 LOCATION AND ORIENTATION 8 5 EXTERNAL CONNECTIONS 9 5 1 CURRENT POWER...
Page 3: ...rLine LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK BELGIUM p 3 16 T 32 3 293 35 50 www lux lumen com 1 Picture 1 1 General StarLine profile with long throw optic StarLine profile with medium throw opt...
Page 4: ...StarLine LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK BELGIUM p 4 16 T 32 3 293 35 50 www lux lumen com 2 Dimensions...
Page 5: ...manual and ensure yourself that you completely understand its content Observe the safety precautions in this manual Install and operate the led profile only as described in this manual and in conform...
Page 6: ...ons Please ensure yourself that the AC to DC power supply is able to deliver the rated current requirements of the installation If any cable seal or housing is damaged cracked or reformed disconnect t...
Page 7: ...es are securely fastened Verify that the led profile is firmly fixed to its supporting underground 3 5 Disposing of this product This led lighting device is manufactured in compliance with directive o...
Page 8: ...lf that there is sufficient and unrestricted air flow around the StarLine led profile 4 1 Unpacking The following items are included in your package LED fixture Protective antistatic packaging with sh...
Page 9: ...rranty is void Power supply Rated current The rated input current of the StarLine Led profile is 350mA There are no electronics on board Please note never apply a 12 V or 24 V DC to the units This wil...
Page 10: ...according to EN 61547 2009 General EMC immunity requirements lighting eq EN 61000 4 1 2006 General immunity testing techniques EN 61000 4 2 2008 ESD immunity test EN 61000 4 3 2006 A1 2007 Radiated i...
Page 11: ...aluminum profile with epoxy raisin The StarLine led profile uses a current controlled power supply able to supply 350mA and all modules are connected in series Please note that dangerous voltages can...
Page 12: ...allow all electronic devices to discharge and cool down before executing any service or maintenance 8 2 Cleaning The StarLine led profile itself Extensive dirt and particle build up degrades performa...
Page 13: ...e borne by the customer Limitations Lux Lumen will not warrant the following Periodic check ups maintenance and repair or replacement of parts due to normal wear and tear Consumables Any software Defe...
Page 14: ...ct Defects caused by improper condition of the power supply network Inadequate packaging of the product when returning it under the RMA procedure Accidents or disasters or any cause beyond the control...
Page 15: ...RMA document we cannot accept the material The procedure to obtain a RMA Step 1 Customer contacts Lux Lumen about warranty defects if material has to be returned Step 2 Lux Lumen sends the customer a...
Page 16: ...n com 10 List of used abbreviations AC Alternating current DC Direct current F Temperature in degrees Fahrenheit C Temperature in degrees Celsius LED Light Emitting Diode CRI Color Rendering Index Lm...