Control
System setup
34
Solenoid-Diaphragm Dosing Pump
MAGDOS LP
© Lutz-Jesco GmbH 2014
Operating Instructions
BA-10231-02-V03
10.6.2 Set "Date" menu item
1.
Use the
or
key to choose the
Date
menu item and press
Setup
.
2.
Use the
+
and
-
keys to set the desired day and press
Next
.
3.
Use the
+
and
-
keys to set the desired month and press
Next
.
4.
Use the
+
and
-
keys to set the desired year and press
Next
.
5.
Use the
+
and
-
keys to set the desired day of the week.
6.
Press
Back
.
The date is set.
10.6.3 Set "Language" menu item
1.
Use the
or
key to choose the
Language
menu item and press
Setup
.
You can choose from the following options:
English
(factory default setting),
Deutsch,
Francais,
Espanol,
Portugues,
Nederlands,
2.
Use the
or
key to choose a language and press
OK
.
The language is set.
10.6.4 Set "Units" menu item
Fig. 10-8: Display of the unit of delivery capacity
1.
Use the
or
key to choose the
Units
menu item and press
Setup
.
You can choose from the following units:
Litres/Day,
Litres/Hr.
USgal/Day (American gallons),
USgal/Hr. (American gallons),
I.gal/Day (Imperial gallons),
I. gal / Hr. (Imperial gallons),
ml/Min.
2.
Use the
or
key to choose the desired unit and press
OK
.
The unit is set.
10.6.5 Set "Alarm relay" menu item
Using the alarm relay, it is possible to forward outwards disturbances on
the dosing pump.
For information on the connection, see “Alarm relay output” on page 30.
1.
Use the
or
key to choose the
Alarm relay
menu item and
press
Setup
.
You can choose from the following options:
Not active
(factory default setting),
NO relay
(Normally open),
NC relay
(Normally closed).
2.
Use the
or
key to choose the desired function and press
OK
.
The "alarm relay" is set.
10.6.5.1 "Alarm relay" configuration
NC relay
NO relay
10.6.6 Set "Level input" menu item
Level monitoring of the dosing medium feed on the suction side with
two alarm stages: Alert and main alarm
For more details on installing the level monitoring system, see “Level
monitoring” on page 25.
For information on the connection, see “Level input” on page 30.
1.
Use the
or
key to choose the
Level input
menu item and
press
Setup
.
If you want to use the MAGDOS LP dosing pump's
Batch
mode
function, you must set the correct day of the week.
i
Manual mode
Menu
Start
-
+
100%
0.06
Liter
h
Situation
Alarm relay output
Relay
Voltage
supply
Fault
Pins 1/4
Pins 2/4
No
No
closed
Open
inactive
Yes
closed
Open
inactive
Yes
No
Open
closed
active
Yes
closed
Open
inactive
Table 10-7: Configuration of NC relay
Situation
Alarm relay output
Relay
Voltage
supply
Fault
Pins 1/4
Pins 2/4
No
No
closed
Open
inactive
Yes
closed
Open
inactive
Yes
No
closed
Open
inactive
Yes
Open
closed
active
Table 10-8: Configuration of NO relay