background image

030-1307

 6

 

Mount and align control.  Install wallplate (purchased separately).

 7

  Turn power on.

 5

  Wiring the control.

•  Connect the 

green

 dimmer wire to 

the bare copper or green ground 

wire in the wallbox, if present (see 

Important Note 5).

•  Using a wire connector, connect 

the 

black

 dimmer wire to either 

of the wires removed from the 

switch.

•  Using a wire connector, connect 

the 

red

 dimmer wire to the 

remaining wire removed from the 

switch. 

•  Using a wire connector, cap off 

the 

red/white

 dimmer wire. This 

wire is not used in a single pole 

circuit.

•  Connect the 

green

 dimmer wire to 

the bare copper or green ground 

wire in the wallbox, if present

  (see Important Note 5).
•  Using a wire connector, connect 

the 

black

 dimmer wire to the 

wire removed from the different-

colored screw on the switch 

(marked or tagged wire). Remove 

tag from wire.

•  Using a wire connector, connect 

the 

red

 dimmer wire to either 

of the remaining wires removed 

from the switch.

•  Using a wire connector, connect 

the 

red/white

 dimmer wire to the 

remaining wire removed from

  the switch.

Installation

For installations involving more than one control in a wallbox, refer to Multi-Unit 

Installations before beginning.

 1

 

Turn power off at circuit breaker or remove fuse.

 

2

 

Remove wallplate.  Pull switch from wall.

 3

  Identify type of switch:

 

 4

  Disconnecting switch wires.

Lutron Electronics Co., Inc.

7200 Suter Road

Coopersburg, PA 18036-1299, U.S.A.

Made and printed in U.S.A.

5/10 P/N 030-1307  Rev. A

Single Pole / 3-Way
Tu-Wire

®

 Fluorescent Controls

Rated at 120 V   60 Hz

5 A maximum total current

Important Notes

Please read before installing.

1.   

CAUTION:

  To avoid overheating and possible damage to other equipment, 

do not use to control receptacles, motor-operated or transformer-supplied 

appliances.

2.  Use only to control Lutron Tu-Wire

®

 fluorescent dimming ballasts.

3.  For proper dimming performance lamps must be operated at full intensity 

for 100 hours prior to dimming.

4.  Only one control can be used in a 3-way circuit.
5.  When no “grounding means” exist within the wallbox then the NEC

®

 

2008, Article 404.9 allows a dimmer without a grounding connection to be 

installed as a replacement, as long as a plastic, noncombustible wallplate 

is used. For this type of installation, cap or remove the green ground wire 

on the dimmer and use an appropriate wallplate such as Fassada

®

 series 

wallplates by 

Lutron

.

6.  For new installations, wire a test switch before installing the control.
7.  Control may feel warm to the touch during normal operation.
8.  Install in accordance with all national and local electrical codes.

Multi-Unit Installations

When combining controls in a wallbox, remove all inner side sections prior 

to wiring (see below).  Use pliers to bend side section up and down until it 

breaks off.  Repeat for each side section to be removed.  Reduction of control 

capacity is required.  Refer to chart below for maximum control capacity.

  

Black

Red

Ground

Red/White

Green

OR

Turn screws to 

loosen

Ground

(Bare Copper or 

Green Wire)

Different-Colored Screw

 (Common)

       Tag

3-WAY:

Insulated wires connected to three screws.  

MARK or TAG

 insulated wire connected to 

different-colored screw or screw labeled 

COMMON.

Ground

(Bare Copper or 

Green WIre)

SINGLE POLE:

Insulated wires connected to two same

color screws.

OR

Backwired:

Insert screwdriver. Pull out wire.

Terminal Screws: 

Turn screw to loosen

   

No sides  

1 side 

2 sides

   

removed 

removed 

removed

  Maximum Current 

5 A 

4 A 

3.3 A

   

To determine total ballast load, add the line current found on the ballast label 

for all ballasts in the circuit. This will indicate the total load for the control.

When making wire connections, twist and 
trim wires to the proper length as indicated:

Note:

  Wire connectors provided are 

suitable for 

copper wire only

. For 

aluminum wire, consult an electrician. Use 
connectors to join one 14 AWG (1.5 mm²) 
supply wire with one 16 AWG or 18 AWG 
(1.0 mm² or 0.75 mm²) control wire.

Twist wire 

connector tight.

Be sure no 

bare wire is 

exposed.

3/8 in

Twist wires

and trim.

Lutron

®

Tu-Wire

®

ballast

Live

Black

Red/White

Red

Green

Neutral

Load

3-Way Switch

120 V~ 

60 Hz

Ground

Lutron

®

Tu-Wire

®

ballast

Live

Load

Neutral

Black

Red

Red/White

Green

Ground

120 V~ 

60 Hz

Limited Warranty

(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)

Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For 

warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299,  postage pre-paid.

THIS WARRANTY IS IN LIEU OF ALL OTHER ExPRESS WARRANTIES,  AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED 

TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, 

OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES 

NOT COVER INCIDENTAL OR CONSEqUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN 

CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER ExCEED THE PURCHASE 

PRICE OF THE UNIT.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow 

the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above 

limitations may not apply to you. 

Lutron, Tu-Wire, and Fassada are registered trademarks of Lutron Electronics Co., Inc. © 2010 Lutron Electronics Co., Inc.

• Easy-to-follow 

Instructions

• Instructions

  faciles à suivre

• Easy-to-follow

 

Instructions

• Instructions

 f

aciles à suivre

Remove All Inner 

Side Sections 

(shaded)

Do Not Remove 

Outer Side Sections

Start screws

Align control and 

tighten screws

Note: 

For proper dimming performance lamps must be 

operated at full intensity for 100 hours prior to dimming.

ON

OFF

ON

OFF

ON

OFF

WARNING:

 Shock Hazard. May result 

in serious injury or death. 

Turn off 

power at circuit breaker before 

installing the unit.

SINGLE POLE circuit

Black

Red

Green

Tag

Ground

Red/White

3-WAY circuit:

English

Important Wiring Information

Models:

DVFTU-5A3P
DVSCFTU-5A3P
SFTU-5A3P

Technical Assistance

If you have questions concerning the installation or operation of this 
product, call the 

Lutron Technical Support Center

. Please provide 

exact model number when calling.

U.S.A. and Canada (24 hrs/7days)  

1.800.523.9466 
México  

+1.888.235.2910
Other countries 8am – 8pm ET 

+1.610.282.3800

Fax

 +1.610.282.6311

http://www.lutron.com

Lutron Technical Support Center     1.800.523.9466     24 hrs / 7 days     www.lutron.com