Lutron Electronics SP-8001 Operation Manual Download Page 1

9 in 1

Anemometer, Humidity/Temp. meter, Light meter
Pt 1000 Temp. ( optional )

Sport/Weather meter

ENVIRONMENT METER

Model : SP-8001

Your purchase of this 9
in 1 METER marks a
step forward for you

into the field of
precision measurement.
Although this METER is
a complex and delicate
instrument, its durable
structure will allow
many years of use if
p r o p e r   o p e r a t i n g
t e c h n i q u e s   a r e
developed. Please read
t h e   f o l l o w i n g
instructions carefully
and always keep this
manual within easy
reach.

       OPERATION MANUAL

Summary of Contents for SP-8001

Page 1: ...s a step forward for you into the field of precision measurement Although this METER is a complex and delicate instrument its durable structure will allow many years of use if p r o p e r o p e r a t...

Page 2: ...ver 6 3 10 Button operation label 6 3 11 Pt 1000 ohm probe socket 6 4 MEASURING PROCEDURES 7 4 1 Power on off 7 4 2 LCD backlight on off 7 4 3 Function selection 7 4 4 Unit selection 8 4 5 Reverse the...

Page 3: ...riction ball bearing mounted wheel design provides high accuracy at high and low air velocity Exclusive photo diode and color correction filter light sensor spectrum meets C I E photopic High precisio...

Page 4: ...dex 9 Pt 1000 ohm Temp optional Operating Max 80 RH Humidity Operating 0 to 50 C 32 to 122 F Temperature Over Input Indication of Display Power Supply CR 2032 DC 3V battery Power Approx DC 5 mA Consum...

Page 5: ...0 1 32 to 122 0 1 Remark ft min feet per minute MPH miles per hour m s meters per second knots nautical miles per hour km h kilometers per hour Humidity Temp Unit Range Resolution Accuracy RH 10 to 9...

Page 6: ...fer to http en wikipedia org wiki Dew_point Wet bulb Temp Unit Range Resolution Remark 5 4 to 49 0 0 1 Calculate from the 22 2 to 120 0 1 humidity Temp value Please refer to http en wikipedia org wiki...

Page 7: ...sult in heat cramps 32 41 90 105 Extreme caution Heat cramps and heat exhaustion are possible Continuing activity could result in heat stroke 41 54 105 130 Danger Heat cramps and heat exhaustion are l...

Page 8: ...1 Hold button 3 2 Button Power button 3 3 REC nutton 3 4 LCD display 3 5 Wristlet 3 6 Light Sensor 3 7 Anemometer Vane 3 8 Humdity Temp sensor 3 9 Battery Compartment Cover 3 10 Button operation labe...

Page 9: ...off 4 2 LCD backlight on off During power on press Power Button once then the LCD backlight will be on 5 seconds then off automatically 4 3 Function selection The meter can select 9 kind function as a...

Page 10: ...t Heat index LIgHt Light Pt Pt 1000 ohm Temp optional Until the Display show the desired function just release the Hold button the meter will execute this function with default 4 4 Unit selection 1 Du...

Page 11: ...tton to save the lower Display unit with default The selection unit for all function are Measurement Unit Air velocity M S Km h mph knot FPM Temp Air velocity Air flow CMM CFM Wind chill Temp Humidity...

Page 12: ...fer to chapter 4 3 now the meter is ready for Air flow measurement 2 Set the measurement area dimension Press the Hold button once the Display will show the indicator HOLD then press the REC button co...

Page 13: ...mum value will appear on the display b Press the REC button again the MIN symbol along with the minimum value will appear on the display c To exit the memory record function press the REC button conti...

Page 14: ...refer to chapter 4 3 now the meter is ready for Pt 1000 ohm Temp measurement 5 BATTERY REPLACEMENT 1 When the LCD display shows symbol it is necessary to replace the battery However measurement may st...