The 

RadioRA 

Network Control Interface (NCI) allows

you to control lighting throughout your home–via any
popular web browser–while utilizing an existing home 
network.

Overview

Before you can begin using the NCI, you need to set
up and program the 

RadioRA 

system.

The RS232 Interface or Chronos

TM

System Bridge and

Timeclock must be installed and RS232 Scenes pro-
grammed for the NCI to access them. Refer to the
RS232 Interface Setup and Installation Guide 
(P/N 044-005) or the 

Chronos

Setup and Installation

Guide (P/N 044-037) for more information.

In addition, you must have at least the following:

• PC or other web browser-enabled device capable

of browsing the NCI setup pages (

Note: 

Do not

connect the NCI directly to a PC)

• Available port on a home or office network with a

DHCP Server (commonly found in a router, but
not in a hub or switch)

• RA-NET-120 hardware

Important Notes

Codes: 

Install in accordance with all local and 

national electrical codes.

Power: 

Use only the adapter provided with the NCI. 

Caution - 

Using an adapter not rated for

the following specifications could damage
the NCI and possibly overheat the adapter.

• Input: 120 V

60 Hz 6 W

• Output: 12 V

300 mA 

NEC Class 2; IEC PELV

Environment: 

Ambient operating temperature: 

0-40 °C, 32-104 °F, 0-90% humidity, non-condensing.
Indoor use only.

Cleaning: 

To clean, wipe with a clean damp cloth.

DO NOT 

use any chemical solutions. 

DO NOT 

paint

the NCI.

Mounting: DO NOT 

ground the NCI. 

Setup: 

The NCI will not function until it is configured

and connected to a 

RadioRA

system that has already

been setup.

Dimensions

Power Adapter
Input: 

120 V

60 Hz  6 W

Output:  12 V

300 mA

NEC Class 2 
IEC PELV

Network Control Interface
12 V

300 mA

5 in. 

(128 mm)

4 5/8 in.

(117 mm)

2 3/4 in.
(72 mm)

1 1/2 in.
(38 mm)

5/8 in.

(17 mm)

1 1/8 in. 
(28 mm)

3 3/4 in.
(95 mm)

Serial Cable 
18 in. (45.725 cm)

Ethernet (Cat5) Cable
3 ft. (91.44 cm)

Drywall Anchors (4)

Mounting Screws (4)

Masonry Anchors (4)

Mounting Screws (4)

1 1/2 in.
(38 mm)