LUXOR
Page 1: ...Lutron RadioRA 2 Lighting Accessories by Hunter Industries Integration Guide Luxor Controllers with ZD Technology and ZDC Technology LUXOR ...
Page 2: ...le of Contents 3 System Requirements 3 Getting Started 4 Adding Devices 8 Integration IDs 9 Telnet Logins 10 Programming Keypads 12 Project Transfer 13 Luxor Controller Configuration 15 Troubleshooting LUXOR ...
Page 3: ... 1 Open the RadioRA 2 project 2 In the DESIGN tab locate the Main Repeater by pressing the Find Main Repeater button System Requirements RadioRA 2 System Requirements Software RadioRA 2 Essentials or RadioRA 2 Inclusive ...
Page 4: ...d record the IP address Note The Main Repeater IP address will be added to the Luxor controller 4 Press Save Settings 5 In the Design tab press to add a Room Note Names should correspond to areas e g Backyard Palms etc being turned ON by the Luxor controller ...
Page 5: ...5 Adding Devices Adding Devices Devices are used as placeholders for each Luxor controller Group 1 In the recently assigned Room press click here to add a device location and select RF Maestro Tabletop ...
Page 6: ...tion and Zone Name fields 3 Click Done 4 Click Click here to add a device location and select RF Maestro Tabletop 5 Enter LuxorGroup1 in the Device Location field and Luxor1 in the Zone Name field Device Location LuxorGroupX Zone Name LuxorX X Luxor Group number ...
Page 7: ...dding Devices 6 Click Done 7 Continue adding RF Maestro Tabletop devices until the number of devices equals the number of Luxor groups Note Luxor All Groups device should now be listed in Available Devices ...
Page 8: ...tab 2 Click the IDs tab 3 Double click Integration ID for Luxor All Groups device and enter 500 4 Double click Integration ID and enter 501 for the device named Luxor1 Continue this process for the remaining devices reserved for Luxor groups 5 Click OK once all Luxor group Integration IDs have been updated ...
Page 9: ...e Integration Settings tab 2 Click the Telnet Logins tab 3 Click Click here to create a new Telnet login 4 Enter hunter in Username field 5 Enter 4HHuunntteerr in the Password field Note Bad Login message will appear if username and password do not match steps 4 and 5 6 Click OK ...
Page 10: ... from the menu bar and select a Keypad to operate Luxor Groups 2 Select the room where Luxor Groups are located 3 Select keypad button that will be used to turn on Luxor Groups 4 Set the desired dimming level 0 100 Note Fade Time remains set at 0 5 Click Done ...
Page 11: ...1 Programming Keypads 7 Repeat steps 1 6 for Keypads and buttons to be used on Luxor Groups Note Luxor Groups devices are only placeholders and do not need to be activated within the Essentials software ...
Page 12: ...nsfer Project Transfer 1 Select the Transfer tab in menu bar and select Start Transfer Note Ignore all Device not addressed warnings Luxor Group devices do not need to be activated since they are used as placeholders ...
Page 13: ...13 Luxor Controller Configuration Luxor Controller Configuration 1 From the Luxor home screen select Setup 2 Select Wi Fi or LAN for hardwire connection ...
Page 14: ...e Lutron IP address Note The IP address can be found on the Main Repeater refer to page 4 6 Enter 500 in the Integration ID Start field Enable Lutron 7 Select the Lutron Enabled box 8 Confirm Connected to Lutron Note The Luxor controller will attempt to connect if the Lutron system is running ...
Page 15: ...ct verify the Lutron IP address is correct Bad Login Message The Bad Login error message occurs when the Lutron login username and password do not match hunter and 4HHuunntteerr refer to page 9 If changes are made the project will need to be transferred again refer to page 12 ...
Page 16: ...ries com LP 003 IG RA2 RevB US 6 19 Lutron and RadioRA are trademarks of Lutron Electronics Co Inc registered in the U S and other countries 2019 Hunter Industries Inc Hunter all related logos and all other trademarks are property of Hunter Industries registered in the U S and other countries ...