background image

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 10/06 P/N 030-834 Rev. B

Technical Assistance

If you have questions concerning the installation or operation of this product, call the 

Lutron Technical Support Center

.

 Please provide exact model number when calling. 

1-800-523-9466 (U.S.A., Canada, and the Caribbean)
Other countries call +1-610-282-3800   
Fax +1-610-282-3090 

 

Internet www.lutron.com

Limited Warranty

(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)

Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place 
of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299,  postage pre-paid.

THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES,  AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM 
PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, 
OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES.

 

LUTRON’S LIABILITY 

ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL 
NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.

 

This warranty gives you specifi c legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you. 
This product may be covered under one or more of the following U.S. patents: 6,774,328; 7,105,763; D477,572 and corresponding patents of other countries. U.S. 
and other patents pending. Lutron is a registered trademark and Qoto is a trademark of Lutron Electronics Co., Inc. 
© 2006 Lutron Electronics Co., Inc.

English

Single-Pole Switch

Q-1PS

3-Way Switch

Q-3PS

Rated at 120/277 V~  60 Hz  15 A

Purchase Lutron wallplate separately.

Important Notes

Please read before installing

1. 

Connect only No. 12 or 14 AWG gauge copper or copper 
clad wire to switch. See device for strip length.

2.

 Do not connect aluminum wire to this device. 

3.

 Install in accordance with all national and local electrical 

codes.

4. 

Clean unit with a 

soft damp cloth only

. Do not use any 

chemical cleaners.

Multi-Unit Installations

When combining controls in a wallbox, remove all inner side sections prior to 
wiring (see below). Use pliers to bend side section up and down until it breaks 
off. Repeat for each side section to be removed. 

Note:

 No derating required if 

ganged.

Each control has 

inside section 

removed.

Middle control has 

two side sections 

removed.

Ground
(Green screw)

Turn screws 
counterclockwise 
to loosen.

Ground 
(bare 
copper or 
green wire)

SINGLE-POLE circuit:

Insulated wires connected to two 
screws of the same color. Replace with 
a single-pole or 3-way switch. Follow 
wiring “Single-Pole Wiring” when 
completing Step 6a.

Push-in Terminals: Insert wires fully.
NOTE:  Push-in terminals are for 
use with #14 AWG 

solid copper wire 

only.

 For aluminum wire, consult an 

electrician. DO NOT use stranded or 
twisted wire.

Ground 
(bare 
copper 
or green 
wire)

Different-colored 
screw (Common)

Tag

3-WAY circuit:

Insulated wires connected to three 
screws. One of these wires is 
connected to a screw of a different-
color or labeled COMMON. 

Tag

 this 

wire to identify it when wiring. Follow 
wiring “3-Way Wiring” when completing 
Step 6b.

OR

OR

Screw Terminals: Tighten securely. 
Screw terminals are for use with 

solid 

copper wire only. 

For aluminum wire, 

consult an electrician. DO NOT use 
stranded or twisted wire.

OR

Turn screws 
clockwise to start.

Align switch and 
tighten screws 
clockwise.

Screw Terminals: 
Turn screws 
counterclockwise 
to loosen.

Backwired:
Insert screwdriver and 
pull wire out.

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Tag

Different-colored 
screw (COMMON)

Ground
(Green screw)

Installation

For installations involving more than one control in a wallbox, refer to 
Multi-Unit Installations before beginning.

Prepare wires. 

Trim or strip wallbox wires to the length 

indicated by the strip gauge on the back of the switch. Use the 
same procedure to wire your new switch as was used with the 
old switch (see Step 4 and below).

Disconnect switch wires.

2

1

5

4

WARNING: Turn power OFF at circuit breaker or remove fuse.

Remove switch mounting screws. Pull switch from wall.

3

Identify type of circuit.

1/2” 

(13 mm)

Turn power ON.

Mount and align switch. Replace wallplate.

Wire the switch.

8

7

6

• Connect the bare copper or 

green ground wire to the green 
ground screw on the switch.

• Connect one of the insulated 

wires removed from the 
switch to either of the screws 
(or push-in terminals) on the 
switch.

• Connect the other insulated 

wire removed from the switch 
to the other screw (or push-in 
terminal) on the switch.

• 

Note: 

If you are replacing 

a single-pole switch with a        
3-way switch, the screw on the 
opposite side of the different 
colored screw, is not used. 
Tighten it securely and follow 
instructions for single-pole 
wiring.

• Connect the green or bare 

copper ground wire to the 
green ground screw on the 
switch.

• Connect the Tagged wire 

removed from the switch to 
the different-colored screw 
(COMMON) (or push-in 
terminal) on the switch.

• Connect one of the remaining 

wires removed from the switch 
to either of the remaining 
screws (or push-in terminal) on 
the switch.

• Connect the last wire removed 

from the switch to the 
remaining screw (or push-in 
terminal) on the switch.

120/277 V~

60 Hz

Neutral

Ground

3-Way 

Switch

3-Way

Switch

Ground

Live

Light

120/277 V~

60 Hz

Neutral

Ground

Single-Pole 

Switch

Live

Light

Reference Wiring Diagram

Reference Wiring Diagram

OR

 6a - Single-Pole Wiring

 6b - 3-Way Wiring

Important Note:

 Your wall switch may have two wires attached to the 

same screw (see illustrations below for examples). Tape these two 
wires together before disconnecting. When wiring, connect wires to the 
dimmer the same way there were connected to the switch.

One wire in the 
backwired hole and one 
to the screw.

One continuous wire 
to the screw.

030-834

• 

Easy-to-follow 
Instructions

• 

Instrucciones 
Fáciles de Seguir

• 

Easy-to-follow 
Instructions

• 

Instrucciones 
Fáciles de Seguir

030-834

Lutron Technical Support Center     1-800-523-9466     24 hrs / 7 days     www.lutron.com