Lutron Electronics PM-9100HA Operation Manual Download Page 1

2000 mbar, differential input

MANOMETER

Model : PM-9100HA

Your purchase of this
MANOMETER marks a step
forward for you into the
f i e l d   o f   p r e c i s i o n
measurement.  Although
this MANOMETER is a
complex and delicate
instrument, its durable
structure will allow many
years of use if proper
operating techniques are
developed. Please read
the following instructions
carefully and always keep
this manual within easy
reach.

       OPERATION MANUAL

Summary of Contents for PM-9100HA

Page 1: ... you into the field of precision measurement Although this MANOMETER is a complex and delicate instrument its durable structure will allow many years of use if proper operating techniques are developed Please read the following instructions carefully and always keep this manual within easy reach OPERATION MANUAL ...

Page 2: ...RONT PANEL DESCRIPTION 4 3 1 Display 4 3 2 Power Off On Button 4 3 3 Hold Button 4 3 4 Zero Button 4 3 5 MAX MIN Button 4 3 6 Unit Button 4 3 7 P1 input socket 4 3 8 P2 input socket 4 3 9 Battery Compartment Cover 4 3 10 PLug quick coupler 4 4 MEASURING PROCEDURE 5 5 AUTO POWER OFF DISABLE 6 6 BATTERY REPLACEMENT 7 ...

Page 3: ...e front panel Auto shut off saves battery life Zero button on the front panel easy to offset the zero value Microprocessor circuit assures maximum possible accuracy provides special functions and features Super large LCD display with contrast adjustment for best viewing angle Records maximum minimum readings with recall Data Hold function for stored the desired value on display Built in low batter...

Page 4: ...iquids Data hold By push button Data record Record maximum minimum readings Sampling time Approx 0 8 second Power off Auto shut off saves battery life or manual off by push button Operating 0 to 50 32 to 122 temperature Operating Less than 80 R H humidity Power supply 006P DC 9V battery heavy duty Power current Approx DC 8 0 mA Weight 246 g 0 54 LB Dimension 185 x 78 x 38 mm 7 2 x 3 0 x 1 4 inch A...

Page 5: ...h HF2 Atmosphere 1 974 Atmosphere 0 001 Atmosphere Unit Max range Accuracy mbar 2000 mbar 2 F S psi 29 psi Kg cm 2 2 040 Kg cm 2 Note mm Hg 1500 mm Hg 23 5 蚓 inch Hg 59 05 inch Hg F S full scale meter HF2 20 40 meter HF2 Included linearity inch HF2 802 inch HF2 hysteresis and Atmosphere 1 974 Atmosphere repeatability Remark Measuring Display unit unit mbar m Bar psi Psi Kg cm 2 Kg cm 2 mm Hg mm Hg...

Page 6: ...DESCRIPTION Fig 1 3 1 Display 3 7 P1 input socket 3 2 Power Off On Button 3 8 P2 input socket 3 3 Hold Button 3 9 Battery Compartment 3 4 Zero Button Cover 3 5 MAX MIN Button 3 10 PLug quick coupler 3 6 Unit Button 4 ...

Page 7: ...nput socket P1 input socket P2 input socket for accepting the differential pressure input Connecting the pipe along the Plug 3 10 Fig 1 to a P1 input socket 3 7 Fig 1 only b P2 input socket 3 8 Fig 1 only c Both P1 P2 input socket The LCD will show the measuring pressure value Note If the P1 pressure P2 pressure the display will get positive reading If the P1 pressure P2 pressure the display will ...

Page 8: ...ill appear on the display b Press the MAX MIN Button again the Min symbol along with the minimum value will appear on the display c To exit the memory record function press the MAX MIN Button continuously for at least 2 seconds The display will revert to the current reading 8 For quick measurement follow the procedures shown below Main procedures POWER ZERO ADJUST ON DETERMINE UNIT Optional measur...

Page 9: ...ring measurement by pressing the MAX MIN Button 3 5 Fig 1 6 BATTERY REPLACEMENT 1 When the left corner of LCD display show LBT it is necessary to replace the battery However in spec measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate 2 Slide the Battery Cover 3 9 Fig 1 away from the instrument and remove the battery 3 Install ...