background image

2

1.

  Determine the number of switchboxes necessary 

by using the Switchbox Requirement Chart (Table A).  
When ganging any combination of small dimmers 
(N-600, N-1000) and large dimmers (N-1500, N-2000), 
keep all small dimmerstogether at one end of the 
gang and all large dimmers together at the other end 
of the gang.

2.

  When ganging an even number of small 

controls use gangable switchboxes with tapped 
ears.  Do not use plaster rings or gangbox covers.  
One switchbox in addition to the total number of 
controls is required in order to provide space for 
faceplates (e.g. 4 dimmers require 5 switchboxes).  
Place additional switchboxes 

3/4

 in (19 mm) apart 

from other switchbox(es) to provide space for 
faceplate(s).

Multigang Installation-

No Side Sections Removed (No Derating Required)

In multigang installations, several dimmers or controls 
are grouped horizontally in one ganging switchbox 
or in a series of connected switchboxes.  Multigang 
faceplates are available to simplify and improve the 
appearance of this installation.  A multigang mounting 
frame is provided with standard multigang faceplates 
which ensures proper alignment of dimmers, easy 
application of the faceplate, and a fl at surface for the 
installation.  Refer to instruction sheet (supplied with 
multigang faceplate) when using these components.
Installation of dimmers without removing side 
sections allows operation at full capacity (no 
derating).  Follow instructions below.  For retrofi t 
installations side sections can be removed to fi t 
existing switchboxes.  This requires derating and is 
described in 

"

Multigang Installation - Side Sections 

Removed" on page 3.

5.

  Push wires into switchbox, allowing room for 

dimmer backbox to be inserted.

6.

  Mount dimmer to switchbox using the 2 provided 

screws in the center mounting holes (offset 
mounting holes are for multigang installation). 
Unit 

must

 be mounted vertically.

Table A.  Switchbox Requirement Chart

No Side Sections Removed

 

*See item #2

Single-gang 
Wallbox

3/4 in (19 mm) space (use 
chase nipple or Lutron P/N 
“PLUS-ADPTR-3.5”)

Four-gang
wallbox

Ground
(Green or Bare)

7.

 Snap faceplate on dimmer.

8.

 Turn power ON.  Push slider up to increase light 

and down to decrease light.  Full "down" position 
will turn light off.

Offset Mounting Holes

Center Mounting Holes

Press plate Until Tabs Snap In

Faceplate

Tabs

 

  Number of Small Controls

 

  0 1 2 3 4 5 6

 

Number of Switchboxes Required

 

0  0  1 1+1* 4 4+1* 7 7+1*

Number 

1 1 3 5 6 8 9 11

of 

Large 

2 4 6 7 9 10 

12 

13

Controls 

3  6  8  10 11 13 14 16

 

4  9  11 12 14 15 17 18

 

 