background image

Custom Settings (Optional) 

Timeout

1

1

Test Mode

2

2

1 minute

3

5 minutes

3

4

15 minutes

4

5

30 minutes

Sensor Mode (MS-OPS only)

1

Auto-On and Auto-Off

(Occupancy mode)

2

Manual-On and Auto-Off

(Vacancy mode)

3

Auto-On daylight sensing

5

 and

Auto-Off

Advanced Settings

1

Motion sensitivity low

2

Motion sensitivity high

3

Return all settings to default

Number of flashes

 

Number of flashes

 

Number of flashes

 

Occupancy sensing switch

Occupancy sensing switch

NOTES:

Select your preferred settings from the table below before 

proceeding; default settings shown in 

bold

.

For natural light detection, see 

Footnote 5

.

Read all instructions before proceeding.

Press and hold the button(s) indicated in the pictures 

below until the lens begins to flash (approximately 

5 seconds). 

1

The setting is saved after the button is released.

3

The lens will flash once at each setting. 

(Always starts at setting 1.)

EXAMPLE:

 To set the Timeout to 30 minutes, press 

and hold the large button. Release the button after 

the lens flashes for the fifth time (approximately 

3 seconds between flashes).

2

1

  Timeout is the delay until lights go off after room is 

vacated.

2

  Short (less than 15-second) timeout for testing sensor 

coverage. After entering, device will exit test mode 

automatically after 5 minutes, or when any button is 

pressed.

3

  MS-OPS5M and MS-VPS5M default.

4

  MS-OPS6M2-DV, MS-VPS6M2-DV, UMS-OPS6M2-DV, 

and UMS-VPS6M2-DV default.

5

  Lights turn on only if natural light in room is low. If switch 

turns on when there is enough natural light, or if switch 

does not turn on when there is not enough natural light, 

press the large button within 5 seconds of entering the 

room. Over time, this interaction will “teach” the switch 

your preferred setting.

Occupancy sensing switch

MS-OPS5M, MS-VPS5M
120 V

~

  50 / 60 Hz

360 W

LFCA

CFL

AFC

CFL 

|

 LFCA 

|

 AFC

LED

DEL

LED 

|

 DEL

450 W

MLV | BVM | BTM

MLV 

|

 BVM 

|

 BTM

600 W

Incandescent 

|

Halogen 

|

 

ELV 

|

 BVE 

|

 BTE

Incandescent | Incandescente

Halogen | Halógena | Halogène
ELV | BVE | BTE

3 A

Combined fan and light load

5 A

Ballast 

|

ro | Ballast

3 A 1/10 HP

entilador

Fan

Ventilateur

 

Fanr

MS-OPS6M2-DV, MS-VPS6M2-DV,  

UMS-OPS6M2-DV, UMS-VPS6M2-DV
120 – 277  V

~

  50 / 60 Hz

6 A

Lighting 

3 A

Combined fan and light load

3 A 1/10 HP

Fan 

120 V

~

  50 / 60 Hz

 Wallplate 

 (if included) 

Adapter plate

Faceplate

Pull forcefully.

Remove 

faceplate.

Replace 

faceplate.