Custom Settings (Optional)
Timeout
1
1
Test Mode
2
2
1 minute
3
5 minutes
3
4
15 minutes
4
5
30 minutes
Sensor Mode (MS-OPS only)
1
Auto-On and Auto-Off
(Occupancy mode)
2
Manual-On and Auto-Off
(Vacancy mode)
3
Auto-On daylight sensing
5
and
Auto-Off
Advanced Settings
1
Motion sensitivity low
2
Motion sensitivity high
3
Return all settings to default
Number of flashes
Number of flashes
Number of flashes
Occupancy sensing switch
Occupancy sensing switch
NOTES:
Select your preferred settings from the table below before
proceeding; default settings shown in
bold
.
For natural light detection, see
Footnote 5
.
Read all instructions before proceeding.
Press and hold the button(s) indicated in the pictures
below until the lens begins to flash (approximately
5 seconds).
1
The setting is saved after the button is released.
3
The lens will flash once at each setting.
(Always starts at setting 1.)
EXAMPLE:
To set the Timeout to 30 minutes, press
and hold the large button. Release the button after
the lens flashes for the fifth time (approximately
3 seconds between flashes).
2
1
Timeout is the delay until lights go off after room is
vacated.
2
Short (less than 15-second) timeout for testing sensor
coverage. After entering, device will exit test mode
automatically after 5 minutes, or when any button is
pressed.
3
MS-OPS5M and MS-VPS5M default.
4
MS-OPS6M2-DV, MS-VPS6M2-DV, UMS-OPS6M2-DV,
and UMS-VPS6M2-DV default.
5
Lights turn on only if natural light in room is low. If switch
turns on when there is enough natural light, or if switch
does not turn on when there is not enough natural light,
press the large button within 5 seconds of entering the
room. Over time, this interaction will “teach” the switch
your preferred setting.
Occupancy sensing switch
MS-OPS5M, MS-VPS5M
120 V
~
50 / 60 Hz
360 W
LFCA
CFL
AFC
CFL
|
LFCA
|
AFC
LED
DEL
LED
|
DEL
450 W
MLV | BVM | BTM
MLV
|
BVM
|
BTM
600 W
Incandescent
|
Halogen
|
ELV
|
BVE
|
BTE
Incandescent | Incandescente
Halogen | Halógena | Halogène
ELV | BVE | BTE
3 A
Combined fan and light load
5 A
Ballast
|
ro | Ballast
3 A 1/10 HP
entilador
Fan
Ventilateur
Fanr
MS-OPS6M2-DV, MS-VPS6M2-DV,
UMS-OPS6M2-DV, UMS-VPS6M2-DV
120 – 277 V
~
50 / 60 Hz
6 A
Lighting
3 A
Combined fan and light load
3 A 1/10 HP
Fan
120 V
~
50 / 60 Hz
Wallplate
(if included)
Adapter plate
Faceplate
Pull forcefully.
Remove
faceplate.
Replace
faceplate.