Wiring
WARNING! Shock Hazard.
May result in serious injury or death.
Turn power OFF at circuit breaker before installing the unit.
1
Turn power OFF
I
I
I
O
O
O
®
Dual Technology Sensor Switch
Installation Guide
Lighting
120 – 277 V
~
50 / 60 Hz 6 A
Fan
120 V
~
50 / 60 Hz 4.4 A 1/6 HP
Combined lighting and fan load
120 V
~
50 / 60 Hz 4.4 A
MS-A102
Occupancy
®
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and
the Caribbean). Lutron will, at its option, repair or replace any unit
that is defective in materials or manufacture within five years after
purchase. For warranty service, return unit to place of purchase or
mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299,
postage pre-paid. This warranty is in lieu of all other express
warranties, and the implied warranty of merchantability is limited to
FIVE years from purchase. This warranty does not cover the cost
of installation, removal or reinstallation, or damage resulting from
misuse, abuse, or damage from improper wiring or installation. This
warranty does not cover incidental or consequential damages.
Lutron’s liability on any claim for damages arising out of or in
connection with the manufacture, sale, installation, delivery,
or use of the unit shall never exceed the purchase price of the
unit.
This warranty gives you specific legal rights, and you may
have other rights which vary from state to state. Some states do
not allow the exclusion or limitation of incidental or consequential
damages, or limitation on how long an implied warranty may last,
so the above limitations may not apply to you.
Lutron and Maestro are registered trademarks of Lutron
Electronics Co., Inc.
© 2014 Lutron Electronics Co., Inc.
Major motion coverage:
30 ft × 30 ft (9 m × 9 m) [900 ft
2
(81 m
2
)]
Minor motion coverage:
20 ft × 20 ft (6 m × 6 m) [400 ft
2
(36 m
2
)]
P/N 032460 Rev. A
07/2014
Troubleshooting
Symptoms
Possible Causes/Solutions
After installation:
• Sensor switch does
not respond to button
presses
OR
• Sensor switch worked
only once or doesn’t
work at all
• Black wire is not connected to
Line/Hot. Swap black and red wires.
• Check wiring; ground wire must be
connected for product to function.
• Wait 10 seconds.
Not all of my sensor
modes are available
while programming
• Sensor modes are limited in the
Vacancy model (MS-A102-V).
Lights do not turn
ON when space is
occupied
• Off-While-Occupied mode is Enabled
and the timeout has not expired.
• Sensor mode is set to Vacancy.
• You may have the Vacancy model
(MS-A102-V).
• Sensor is set to one of the Ambient
Light Detection (ALD) settings and
the room is too bright for the current
light level setting.
• Sensor does not have full view of
the room. Move objects blocking
line-of-sight.
For additional features, wiring help, troubleshooting, and product information
www.lutron.com / DTMaestroInstall
4
Wait for 2 minutes
• The sensor switch will manually control the load after the first 10 seconds.
• Once power has been restored, the sensor switch will automatically control the load after the
first 2 minutes.
Important Notes
Please read before installing.
1.
Ground is required for product to function. If no ground
wire is present, consult a licensed electrician.
2.
When power is applied, the sensor switch can be manually
turned on or off after the first 10 seconds and will
automatically control the load after 2 minutes.
3.
The sensor switch requires an unobstructed view of the
room and line‑of‑sight to detect motion.
4.
Hot objects or moving air currents can affect the
performance of the sensor switch and may cause the
sensor to turn on unexpectedly or maintain its current
state longer than desired.
5.
CAUTION:
To reduce the risk of overheating and possible
damage to other equipment,
DO NOT
use to control receptacles.
6.
Install in accordance with all national and local electrical
codes.
7.
For indoor use only. Operate between 32 °F and 104 °F
(0 °C and 40 °C).
8.
Clean with a soft damp cloth only.
DO NOT
use any
chemical cleaners.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036‑1299
www.lutron.com
English
MS-A102-V
Vacancy
3
Turn Power ON
I
I
I
O
O
O
CAUTION! Risk of Electric Shock.
Leakage current present. Earth
connection required before connecting power.
2
Connect sensor switch
• For additional wiring instructions, please visit www.lutron.com/DTMaestroInstall
• Before installing wallplate, program all desired settings. See back for programming
instructions.
Single Pole Wiring
m
30
15
5
1
Occ
Lrn
Fixd
Vac
Mode
Hi
Med
Low
Off
Hi
Med
Low
Min
PIR
Neutral
Black
Red
Load
Green
Green/Yellow
Ground
Line/Hot
120–277 V
~
50 / 60 Hz