background image

220–240 V

~  

50

 

/

 

60 Hz

Hereby, Lutron Electronics Co., Inc. declares that the radio equipment type 

LMM-16R-DV-B are in compliance with Directive 2014/53/EU.

 A copy of the 

DoC can be obtained by writing to: Lutron Electronics Co., Inc. 7200 Suter Road, 

Coopersburg, PA 18036 U.S.A.

Complies with  

ImDA Standards  

DA103083

Lutron Electronics Co., Inc. | 7200 Suter Road 
Coopersburg, PA 18036-1299, U.S.A.

RF Module | Installation

with Softswitch

  Important Notes:

 

•  

For installation by a qualified electrician in accordance 

with all local and national electrical codes. 

• Note:

 Use copper conductors only.

• 

Check to see that the device type and rating is suitable  

for the application.

•  DO NOT

 install if product has any visible damage.

• 

 If moisture or condensation is evident, allow the product 

to dry completely before installation.

• 

Operate between 32 °F to 131 °F (0 °C to 55 °C).

• 

0% to 90% humidity, non-condensing.

• 

For indoor use only.

 

Please read before installing

Warranty: 

For warranty information, please visit 

www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
www.lutron.com/TechnicalDocumentLibrary/Intl_Warranty.pdf

Lutron and Softswitch are trademarks or registered trademarks 
of Lutron Electronics Co., Inc. in the US and/or other countries.   
©2013-2019 Lutron Electronics Co., Inc.

Load 

Status 

LED

Toggle

Advanced 

Operations

For System Setup Guide and tools 
visit www.lutron.com

RF Module

RF Module Operation

Reset Factory Defaults

Note:

 In some instances it may be necessary to 

reset the RF Module back to factory default settings.

A

Triple-tap the Advanced Operations (“ADV”) 

button, on the RF Module and hold until 

the LED begins to flash slowly.

Within 3 seconds of flashing, release and 

triple-tap the button again and the LED 

will flash rapidly indicating that the unit 

has been reset to factory defaults.

B

Note: 

Any associations or programming previously 

set up with the unit will be lost and will need to be 

re-programmed.

English

Customer Assistance

 | 

+91.124.439.0130

  Asia/Middle East

 | 

1.844.LUTRON1

  

USA/Canada

 | 

+1.610.282.3800

  

Others

 | www.lutron.com/support

RF Module can be installed in a junction box or 

marshalling box (optional) using the conduit nut 

(provided) or with mounting screws (not provided). 

Please consult local and national electric codes 

for proper installation.

RF Module Placement

RF Modules must be located within 30 ft (9 m) of an 

RF signal repeater. RF Modules cannot be controlled 

by the system until they are programmed using the 

system programming software.

Shock Hazard. May result in 

serious injury or death. 

 

Turn off power at circuit breaker 

before installing the unit.

WARNING

Installation:

1

2

3

10 mm

Wiring a Lever Operated Connector (shown)

When wiring lever operated connectors (3 supplied) 
please use 14 AWG to 12 AWG (2.5 mm

2

 to 4.0 mm

2

diameter solid or stranded copper wire. 

Troubleshooting

Load does 

not respond 

to Wireless 

Transmitter(s).

•  Ensure breaker to the RF Module 

is on.

•  Ensure the load has been 

properly wired to the RF Module.

•  Ensure that the RF Module has 

been activated in the system.

•  Ensure that the Wireless 

Transmitter battery is installed 
correctly.

RF Module 

does not 

respond to 

a keypad, 

wireless 

controller or 

sensor.

•  

Improper programming.   

Program from the system 
programming software.

•  

Out of RF Range.

 

Reposition to be within 30 ft (9 m) 
of an RF signal repeater.

•  

Already at current level.

 The RF 

Module has already responded to 
a command, or is already at the 
requested setting.

•  

Wireless controller or sensor 
batteries low or installed 
incorrectly. 

Replace or install 

batteries properly.

•  

RF interference.  

Do not run RF Module wires 
with other power wires or 
communication wires (e.g., 
networking, audio, or video 
signals).

To Load

Live (Black)

Neutral (White) 

(White)

21 mm Knockout Opening

Conduit Nut

Switched Hot (Red)

LMM-16R-DV-B

220 – 240  V

~

  50 / 60 Hz  16 A  

6 A Motor 

041706-04 

Rev. A