background image

3

Multi-Location Installation

1

-6D, -10D with HD-RD

120/127VAC
50/60Hz

Black

Green

Hot

Neutral

Red

Blue

Black

Green

Red

Blue

Black

Green

Red

Blue

Lighting
Load

Multi-Location Installation with Neutral

1, 2 

-6ND, -10ND, -5NE with HD-RD, -8ANS with HD-RS

Wiring Diagram 2

Remote Dimmer

Dimmer

120/127VAC
50/60Hz

Black

Green

Hot

Neutral

Red

Blue

Black

Green

Red

Blue

Black

Green

Red

Blue

Lighting
Load

White

2

Remote Dimmers/Switches must be connected on the Line side of a multi-location installation when used with Neutral wire Dimmers or
Switches.

1

Up to 9 HomeWorks

®

Maestro

®

Remote Dimmers/Switches may be connected to the 

HomeWorks Maestro

Dimmer/Switch. Total Blue

wire length may be up to 250' (76m).

Remote

Dimmer/Switch

Dimmer/

Switch

Remote

Dimmer/Switch

Remote Dimmer

Wiring Diagram 1

Summary of Contents for HD-RD

Page 1: ...only suitable equipment is connect ed to these controls Overheat Damage To reduce the risk of overheating and possibly damaging other equipment do not install to control receptacles or motor operated appliances Environment Ambient operating temperature 0 40 C 32 104 F 0 90 humidity non condensing Indoor use only Spacing If mounting one control above another leave at least 4 1 2 114mm vertical spac...

Page 2: ...tors provid ed are suitable for copper wire only Large 3 Wire controls using Wiring Diagrams 1 and 2 page 3 When using power boosters or interfaces use Wiring Diagrams 3 4 and 5 page 4 Up to nine HD RD or HD RS remotes may be connected to the 6D 6ND 10D 10ND 5NE or 8ANS controls 4 Push all wires back into the wallbox and loosely fasten the control to the wallbox using the control mounting screws p...

Page 3: ...VAC 50 60Hz Black Green Hot Neutral Red Blue Black Green Red Blue Black Green Red Blue Lighting Load White 2 Remote Dimmers Switches must be connected on the Line side of a multi location installation when used with Neutral wire Dimmers or Switches 1 Up to 9 HomeWorks Maestro Remote Dimmers Switches may be connected to the HomeWorks Maestro Dimmer Switch Total Blue wire length may be up to 250 76m...

Page 4: ...ck Green White Green N1 H1 DH1 SH1 N N H H DH 1 2 3 N N H H DH 1 2 3 N1 H1 DH1 SH1 N2 H2 DH2 SH2 N3 H3 DH3 SH3 120 277VAC 50 60 Hz Load Circuit Hot Live Neutral Hot Live Neutral Control Circuit Load Terminals Control Terminals Dimmer Switch HP 2 4 6TM Hi Power Module 120 127VAC 50 60 Hz Red Black Blue Green Blue Red Black Wiring Diagram 5 Installation with Neutral and Hi Power Module1 2 6ND 10ND w...

Page 5: ...activates a 10 second long fade to off Lamp Replacement For routine lamp replacement remove power from the fixture s by sliding the Front Accessible Service Switch FASS to the OFF position left After replacing lamps slide the FASS back to the ON position right to restore power Danger For any procedure other than routine lamp replacement power must be disconnected at the main electrical panel Tapsw...

Page 6: ... be sure it agrees with installation instructions and wiring diagrams Tapswitch stuck Tapswitch stuck at another location Check to see that tapswitches are not sticking for all control loca tions in the circuit Load is less than minimum load requirement Make sure the load connected to the dimmer or switch meets the appropriate minimum load require ment for that control See Load Specifications in t...

Page 7: ...7 Notes ...

Page 8: ...NSEQUEN TIAL DAMAGES LUTRON S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE SALE INSTALLATION DELIVERY OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT This warranty gives you specific legal rights and you may also have other rights which vary from state to state Some states do not allow limitations on how long an implied warranty lasts...