Lutron Electronics FORCE GAUGE FG-6005SD Operation Manual Download Page 1

5,000 g

SD Card real time recorder

10 ms sampling time recorder

FORCE GAUGE

Model : FG-6005SD

Your purchase of this
FORCE GAUGE marks a
step forward for you
into the field of precision
measurement.  Although
this FORCE GAUGE is a
complex and delicate
instrument, its durable
structure will allow many
years of use if proper
operating techniques are
developed. Please read
the following instructions
carefully and always keep
this manual within easy
reach.

       OPERATION MANUAL

Summary of Contents for FORCE GAUGE FG-6005SD

Page 1: ...step forward for you into the field of precision measurement Although this FORCE GAUGE is a complex and delicate instrument its durable structure will allow many years of use if proper operating tech...

Page 2: ...AMPLING CHECK Button 6 3 10 RS 232 output terminal 6 3 11 Reset terminal 6 3 12 DC 9V Power Adapter Input Socket 6 3 13 Mounting Holes fixing Screws 6 3 14 Battery Cover Compartment 6 3 15 Flat head A...

Page 3: ...0 second 13 5 4 Peak hold record mode Fast Datalogger 14 5 5 Check time information 15 5 6 Check sampling time information 15 5 7 SD Card Data structure 15 6 Saving data from the SD card to the comput...

Page 4: ...ve the measuring data along the real time value Year Month Date Hour Minute Second into the SD card per normal sampling time 1 second to 8 hours After save the data into the SD memory card it can be d...

Page 5: ...S Display LCD Liquid crystal display 5 digits 16 mm 0 63 digit size Back light Display Positive or Reverse direction select by Direction the push button on the front panel Function Tension Compression...

Page 6: ...ata record Each setting step is 10 mS mode Auto data logger Sampling Time The memory circuit will store 1000 Setting range data no max measuring data Data error no 0 1 of total saved data max Memory C...

Page 7: ...is optional Power Current Normal operation w o SD card save data and LCD Backlight is OFF Approx DC 7 mA When SD card save the data and LCD Backlight is OFF Approx DC 38 mA A If LCD backlight on the p...

Page 8: ...1 PC Chisel head adapter 1 PC 120 mm extension rod 1 PC Carrying case 1 PC Optional T SD memory card 2 GB Accessories Test stand Model FS 1001 Wedge grip Model WG 01 RS232 cable Model UPCB 02 USB cabl...

Page 9: ...3 FRONT PANEL DESCRIPTIONS Fig 1 6...

Page 10: ...REVERSE Button 3 8 TIME SET Button 3 9 LOGGER SAMPLING CHECK Button 3 10 RS 232 output terminal 3 11 Reset terminal 3 12 DC 9V Power Adapter Input Socket 3 13 Mounting Holes fixing Screws 3 14 Battery...

Page 11: ...Pay attention for the measurement 1 Compression measurement the display will show the mark automatically 2 During the measurement the SENSING HEAD along the adapter has to be on a line with measuring...

Page 12: ...ing power on press Power Button 3 3 Fig 1 2 seconds will power off 2 Determine display unit of g oz or Newton by selecting the unit at first with default refer to chapter 7 ADVANCED SETTING 3 Connect...

Page 13: ...operation of fast sampling time measurement If the LCD show SLOW indicator the display reading is under the slow sampling time measurement Over range display of tension function LCD will show Over ran...

Page 14: ...memory card 4 GB Prepare a SD memory card 1 GB to 16 GB optional insert the SD card into the SD card socket 3 20 Fig 1 When plug in the SD card the up side of the SD card should face against the down...

Page 15: ...setting the Decimal point refer to Chapter 7 8 page 24 5 2 Normal record mode Auto Datalogger Set sampling time 1 second a Start the datalogger Press the LOGGER Button 3 9 Fig 1 2 seconds continuously...

Page 16: ...the Datalogger Press the LOGGER Button 3 9 Fig 1 2 seconds continuously the DATA RECORD indicator will be disappeared and finish the Datalogger 5 3 Normal record mode Manual Datalogger Set sampling t...

Page 17: ...1002 Power on the meter 2 Press the PEAK Button 3 6 Fig 1 once the Display will the indicator PEAK and FAST 3 Press the Zero Button 3 4 Fig 1 once the Display will set to ZERO value 4 Press the LOGGE...

Page 18: ...LCD display will present the time information of Hour Minute Second h m s in the lower Display 2 If press Time Button 3 8 Fig 1 once again the lower LCD display will present the time information of Ye...

Page 19: ...e to the FGA01001 XLS until Data column reach to 30 000 columns then will generate a new file for example FGA01002 XLS 3 Under the folder FGA01 if the total files more than 99 files will generate anew...

Page 20: ...nto the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name FGA01001 XLS FGA0...

Page 21: ...EXCEL data screen for example peak hold record mode EXCEL graphic screen for example graphic 1 18...

Page 22: ...ton 3 8 Fig 1 once a while in sequence to select the eight main function the display will show Sd F SD memory card Format dAtE Set clock time Year Month Date Hour Minute Second SP t Set sampling time...

Page 23: ...gain the Display will show text yES Enter to confirm again if make sure to do the SD memory card format then press Enter Button once will format the SD memory clear all the existing data that already...

Page 24: ...When the upper display show SP t 1 Use the Button 3 4 Fig 1 or Button 3 7 Fig 1 to adjust the value Setting start from Hour value After the desired value is set press the Enter Button 3 6 Fig 1 once w...

Page 25: ...usted value range is from 10 ms to 500 ms 2 After set the sampling time value press the SET Button 3 6 Fig 1 once the screen will jump to Auto power OFF setting screen Chapter 7 5 7 5 Auto power OFF m...

Page 26: ...g 1 will save the setting function with default 7 7 Set the measurement unit When the lower display show unit 1 Use the Button 3 4 Fig 1 or Button 3 7 Fig 1 to select the measurement unit in g oz N in...

Page 27: ...elect the upper text to bASIC or Euro USA Use as the Decimal point with default Euro Use as the Decimal point with default 2 After select the upper text to USA or Euro press the Enter Button 3 6 Fig 1...

Page 28: ...y indicator appears before the instrument become inaccurate 2 Loose the screws of the Battery Cover 3 14 Fig 1 and take away the Battery Cover from the instrument and remove the battery 3 Replace with...

Page 29: ...nection will be required to link the instrument with the PC serial port Meter PC 9W D Connector Center Pin Pin 4 3 5 mm jack plug Ground shield Pin 2 2 2 K resister Pin 5 The 16 digits data stream wil...

Page 30: ...no 8 Data bits Stop bit 1 Stop bit 12 MOUNTING HOLES OPTIONAL TEST STAND FORCE GAUGE is a precise instrument best results are obtained when the gauge is fitted to a test stand Mounting holes 3 13 Fig...

Page 31: ...b WEDGE GRIP Model WG 01 Wedge grip the optional accessory to install to the base of FS 1001 be used to hold the tested material FS 1001 WG 01 28...

Page 32: ...ce Test insertion and withdrawal forces of various circuit components such as transistors and integrated circuits Test actuating force of snap action switches 13 2 Business Equipment Measure force req...

Page 33: ...et chain tension Test pull out forced of drive shaft Rate testing of springs in systems Calibrate a cantilever beam type Apparatus to obtain a force deflection relationship 13 5 Automotive Measure for...

Page 34: ...rce to remove cover tops of aerosol cans Measure trigger pulling forces on firearms hand tools etc Test firmness of sausages in casings Test integrity of seals on blister packages and plastic bags Tes...

Reviews: