For each system, ensure that you have:

One PowPak

®

 Dimming Module

At least one Wireless Transmitter

At least one 0 –10 V Fluorescent Ballast or LED Driver

Required Components

Radio Powr Savr

TM

 Occupancy/Vacancy Sensor 

(10 maximum)

Radio Powr Savr

TM

 Daylight Sensor

(1 maximum)

Pico

®

 Remote Control

(10 maximum)

60 mA maximum for the control lines. Switches up to 8 A total. May be 
pre-installed in light fixture.

PowPak

®

 Dimming Module with 0 –10 V 

(1 maximum)

Raise

Toggle

Lower

Load Status LED

Consult third-party 0 –10 V fixtures installation guide for fixture-specific wiring.

Start Here

+

Occupancy Sensors

Daylight Sensor

Wireless Controls

Occupied:

 

All lights 100%.

Unoccupied:

 

All lights off.

Test

Link

Cal.

All lights dim in response to daylight.

On

All lights 100%

Favorite

All lights 50%

Off

All lights off

Default Functionality

Reset Factory Defaults

Note:

 In some instances, it may be necessary 

to reset the PowPak

®

 Dimming Module and 

connected devices back to factory default 
settings. Before beginning, make sure that all 
devices are connected and powered.

A

 Triple-tap the 

Toggle

 button “ 

u

”  on the 

PowPak

®

 Dimming Module and hold until the 

LED begins to flash slowly; release button.

B

  Within 3 seconds of the start of flashing, 

triple-tap the same button again and the LEDs 
will flash rapidly indicating that the unit has been 
reset to factory defaults.

Note:

 Any associations or programming 

previously set up with the PowPak

®

 will be 

erased and will need to be re-programmed.

2

Install PowPak

®

 Dimming Module

Suggested Installation Location: Center of room to ensure proper 
RF coverage of area.

 

A

 PowPak

®

 Dimming Module can be installed in a junction box or 

marshalling box using the conduit nut (provided) or with mounting 
screws (not provided). Please consult local and national electric codes 
for proper installation.

If installing unit inside a junction box, please see Application Note #423 
at http://www.lutron.com/TechnicalDocumentLibrary/048423.pdf

 

B

  Once installed, energize the PowPak

®

 Dimming Module.

 

C

 Use the 

Toggle

 button “ 

u

”  to toggle between high-end and OFF to 

verify ballast wiring.

 

D

 Use the 

Raise 

ŷ

” and 

Lower

 “

Ǻ

” buttons to verify control wiring.

ALL PROGRAMMING IS OPTIONAL

Programming is not required for default functionality

• Set a favorite light level

• Set high-end and low-end trim for all fixtures

• Set occupancy levels

• Set minimum light level for all fixtures

Please consult individual component installation and 
programming guides for more details.

8

Set Minimum Light Level

 

*

Certain applications (e.g., hallways), may 
require that the lights never turn off. For 
these areas, activate Minimum Light Level 
mode.

A

Enter minimum light level adjustment mode:

Press and hold 

Toggle

 button “ 

u

”  and 

Lower

 button “

Ǻ

” for 12 seconds. Lights 

will flash high-low-high and LED will begin 
flashing.

If lights stop flashing and go to high-end, 
the minimum light level is set to OFF 
(default).

If lights stop flashing and go to low-end, 
the minimum light level is ON and set to 
low-end.

B

Change the minimum light level:

Press 

Raise

 button 

 

ŷ

”  to set minimum 

light level to low-end.

Press 

Lower

 button “

Ǻ

” to set minimum 

light level to OFF.

C

Save the minimum light level:

Press and hold 

Toggle

 button “ 

u

”  for 

6 seconds. LED will quickly flash to indicate 
that new level has been saved.

7

Set Low-End and High-End Trim 

*

For best results, minimize the amount of sunlight entering the 
room before performing the following procedures.

Low-End Trim

A

Enter low-end trim adjustment mode:

Press and hold 

Lower

 button “

Ǻ

” for 12 seconds.

Lights will flash high-low-high and LED will begin flashing.

B

Adjust the low-end trim:

Use 

Raise

 button

 

ŷ

”  and 

Lower

 

button “

Ǻ

” to adjust and set the lights 

to the desired low-end (1 to 45%).

 

C

  Save the low-end trim:

Press and hold 

Toggle

 button “ 

u

”  for 

6 seconds to save setting.

LED will begin flashing and then turn 
solid to indicate new level has been 
saved.

High-End Trim

 

D

  Enter high-end trim adjustment mode:

Press and hold 

Raise

 button

 

ŷ

”  for 

12 seconds.

Lights will flash high-low-high and LED 
will flash.

E

  Adjust the high-end trim:

Use 

Raise

 button 

 

ŷ

”  and 

Lower

 

button “

Ǻ

” to adjust and set the lights 

to the desired high-end (55 to 100%).

 

F

  Save the high-end trim:

Press and hold 

Toggle

 button “ 

u

”  for 

6 seconds to save setting.

LED will begin flashing and then turn 
solid to indicate new level has been 
saved.

PowPak

®

 

|

 Programming

English

All Wireless  
Transmitters  
must be installed 
within 30 ft (9 m) of the  
PowPak

®

 Dimming Module.

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299 U.S.A.

0 –10 V Control: 10 V

-

  60 mA

Compatible with ANSI E1.3 2001 (R2006), IEC 60929 Annex E

120 / 277  V

~

  50 / 60 Hz  8 A

RMJS-8T-DV-B

URMJS-8T-DV-B

Radio Powr Savr

TM

Occupancy 

Sensor

Pico

®

  

Remote 
Control

PowPak

®

  

Dimming 
Module

30 ft 

(9 m) max

40 ft (12 m)

33 ft (10 m)

PowPak

®

  

Dimming Module

Install in center of room to  

maximize RF coverage.

Mount, Wire, and Install 0 –10 V Devices and 
Lighting Fixtures

Consult third-party device installation guide

A

Connect mains wiring (switched hot, neutral) to each fixture.

B

Connect 0 –10 V control (+ and – ) to each fixture.

1

+

NEU

HOT

Class 2

MAINS

Fixture Earth

Green/Yellow

To additional 0 –10 V fixtures

Neutral

Switched Line/Hot

Violet

Gray

+

4

Install Wireless Transmitters

Note:

 Please consult individual component installation guides for 

information.

Test

Link

Daylight Override

Lowering the light level from an associated Pico

®

 remote control 

will lower the daylight level. Raising the light level from a Pico

®

 

remote control will temporarily override daylighting for  
2 hours.*

Daylight Re-Enable

Daylighting will return to the calibrated level when one of the 
following occurs:

• OFF has been pressed on a Pico

®

 remote control.

• All associated Occupancy Sensors have reported unoccupied.

* Each time a daylighting override occurs, the two-hour timer is reset.

5

A

Set lights in room to desired light level.

B

Press and hold “Cal.” for 6 seconds.

C

Exit room for 5 minutes to complete calibration.

Note:

 When calibration has completed, all lights will flash and begin daylighting.

Multiple Daylight Rows

 (OPTIONAL)

For every row of daylighting a separate PowPak

®

 Dimming Module must be 

used. For detailed setup refer to the tuning section of the Radio Powr Savr

TM

 

Daylight Sensor installation guide.

•  Select the PowPak

®

 Dimming Module that you want to adjust by pressing the 

toggle button.

Calibrate Daylight Sensor 

*

Daylight Sensor will control all wired fixtures equally.

Test

Link

Cal.

9

Set Occupancy Light Levels 

*

Note:

 Unoccupied light level is always the minimum  

light level and cannot be adjusted.

A

Set desired occupancy light levels:

Use 

Raise

/

Lower

 buttons 

 

ŷ

  /

Ǻ

” on the PowPak

®

 

Dimming Module or 

Raise

/

Lower

 buttons “

”  

on all associated Pico

®

 Remote Controls.

B

Save occupancy light levels:

Press and hold 

Test

 button 

for 6 seconds on any 
associated Radio Powr 
Savr

TM

 Occupancy Sensor 

without a 

Lights On

 button. 

Release when Sensor 
lens starts to flash.

Or, press and hold 

Lights On

 button for 

6 seconds on any 
associated Radio Powr 
Savr

TM

 Occupancy 

Sensor. Release when 
Sensor lens starts to 
flash.

Notes

Depending on the fixture 
manufacturer or load, low-end 
and high-end trim may need to be 
adjusted.

• Trim low-end to ensure a stable 

light level because some loads will 
flicker or drop out if trimmed too 
low.

• Be sure that you can turn on the 

lights to the low-end trim level 
without any abnormal operation.

• The factory default high-end trim 

will normally be sufficient for most 
applications. Trim as desired.

6

Set a Favorite Light Level

 

*

For Pico

®

 Remote Controls with a 

Favorite

 

Button.

A

Adjust lights to desired level:

Use 

Raise

 button “

” or 

Lower

 button “

” 

on Pico

®

 Remote Control.

B

Save favorite level:

Press and hold 

Favorite

 button for 6 seconds.

Raise

Lower

Favorite

Troubleshooting

 

*

                                                                                         

www.lutron.com

Ballasts cannot be controlled locally from 
PowPak

®

 Dimming Module.

•  Ensure that the breaker(s) to the PowPak

®

 Dimming Module are energized.

•  Ensure that the PowPak

®

 Dimming Module switched hot lead is wired to the lighting fixture(s).

•  Ensure that the PowPak

®

 Dimming Module 0 –10 V control lines are wired to the lighting fixture(s).

 

Reset to factory defaults.

Lights do not dim as expected.

•  Ensure that 0 –10 V control lines are wired properly.
•  Ensure that fixture does not require an inverted signal (10 – 0 V control).

Lights do not respond to Wireless 
Transmitter(s).

•  Ensure that the breaker(s) to the PowPak

®

 Dimming Module and ballasts are energized.

•  Ensure that Wireless Transmitters are associated to the PowPak

®

 Dimming Module.

 

Reset to factory defaults.

Lights are unstable at low-end or flash/
flicker at turn-on or turn-off.

•  Adjust low-end trim.

Wireless Transmitter(s) cannot be 
associated to PowPak

®

 Dimming 

Module.

•  The maximum number of Wireless Transmitters have been associated to the PowPak

®

 Dimming Module. To 

remove a previously set up Wireless Transmitter, tap a Wireless Transmitter button three times; on the third tap hold 
for three seconds and then tap three more times.

FCC /IC  Information

This device complies with part 15 of the FCC Rules and Industry Canada license-exempt 
RSS standard(s). Operation is subject to the following two conditions: (1) This device 
may not cause interference, and (2) this device must accept any interference, including 
interference that may cause undesired operation. Modifications not expressly approved by 
Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This equipment 
generates, uses and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television reception, which can 
be determined by turning the equipment off and on, the user is encouraged to try to correct 
the interference by one or more of the following measures:
• Re-orient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver 

is connected.

Warranty:

 For warranty information, please see  

the Warranty enclosed with the product, or visit 
www.lutron.com/TechnicalDocumentLibrary/369-119_Wallbox_Warranty.pdf

Although every attempt is made to ensure that catalogue information is 
accurate and up-to-date, please check with Lutron EA before specifying or 
purchasing this equipment to confirm availability, exact specifications, and 
suitability for your application.
Lutron, Pico, PowPak, and Energi TriPak are registered trademarks and Radio 
Powr Savr and Vive are trademarks of Lutron Electronics Co., Inc.
©2013-2015 Lutron Electronics Co., Inc.

Technical Assistance:

U.S.A. / Canada: 1.800.523.9466
United Kingdom: 0800.282.107
Europe: +44.(0)20.7680.4481
Mexico: +1.888.235.2910
China: 800.901.849
Central / S. America: +1.610.282.6701
Other Countries: +1.610.282.3800

WARNING! Shock Hazard. 

May result in serious injury or death. Turn off power at circuit 

breaker before installing the unit.

UL 2043 Plenum Rated

Sample  
ballast shown

Switched Line/Hot (Red)

Line/Hot 
 (Black)

To Fixtures

0 –10 V to Fixtures*

Neutral (White)

+

Neutral

Junction Box

1/2 in (21 mm) Knockout Opening

Conduit Nut

*  Use 18 AWG to 16 AWG (0.75 mm

2

 to 1.5 mm

2

) solid wire only

Associate Wireless Transmitters to PowPak

®

 Dimming Module 

*

A

 

On PowPak

®

 Dimming Module, 

hold 

Toggle

 button “ 

u

”  for 6 

seconds until lights flash.

The Load Status LED will begin
flashing twice per second.

Before beginning this step, make sure that there are no other PowPak

®

 modules being set up within the same building. It is possible that wireless transmitters from other systems can be incorrectly associated to this module.

3

B

 

Hold the indicated button on each transmitter for 6 seconds. Lights will flash to show that wireless transmitters have been associated.

C

 

On PowPak

®

 Dimming Module, hold 

Toggle

 button “ 

u

”  for 6 seconds to save association. Lights will flash and LED will quickly blink 

for 2 seconds.

Test

Link

Important Notes: 

Please read before installing.

For installation by a qualified electrician in accordance with all 

local and national electrical codes.

• 

Note:

 Use copper conductors only.

• 

Check to see that the device type and rating is suitable for the 

application.

• 

DO NOT

 install if product has any visible damage.

• 

If moisture or condensation is evident, allow the product to dry 

completely before installation.

• 

Operate between 32 °F and 104 °F (0 °C and 40 °C) ambient.

• 

0% to 90% humidity, non-condensing.

• 

For indoor use only.

Note for Replacement:

RMxS and URMxS - the "S" model can replace the 
non-"S" model

*

   For set-up, programming, and troubleshooting 

with a Vive

TM

 system, please refer to the 

installation instructions included with the  
Vive

TM

 hub or at www.lutron.com

Reviews: